Prince Castle 625-A625-A Temperature Adjustment, View Firmware Version, Manual Reset, set temp

Models: 625-A625-A

1 12
Download 12 pages 61.31 Kb
Page 3
Image 3
Temperature Adjustment

S t e a m e r 6 2 5 - A

Temperature Adjustment

A. Press and hold the TEMPERATURE button. The display will 1 show the current temperature setting for Celsius (C) or

Fahrenheit (F).

B. While holding the TEMPERATURE button, press the C/F button to change the setting between Fahrenheit and Celsius.

C. Release the TEMPERATURE button to store the new value.

2

A. Press and hold the Steamer LOGO button first, then

press and hold TEMPERATURE button for approximately

6 seconds.

The display will show SET TEMP.

B. Press the Steamer LOGO button again to display the current set temperature.

 

129 C

 

 

255 F

 

 

 

 

 

 

3

Platen temperature can be set between 129°-152°C (265°- 305°F).

Pre-set at factory to 140°C (285°F) .

 

 

A. Press the UP or DOWN Arrow buttons to scroll to the desired temperature.

B. Press the Steamer LOGO button to store the desired temperature and exit the SET TEMP mode.

NOTE: Pressing the PRODUCT 3 button at any time exits the Program mode without storing the change.

 

TEMP 275

TEMP 275

 

 

 

5

A. Press the UP or DOWN Arrow buttons until the temperature

readout matches the calibration reading.

B. Press the Steamer LOGO button to store the desired tem- perature and exit CAL TEMP mode.

NOTE: Pressing the Product 3 button at any time exits the

set temp

 

255

 

 

 

 

 

 

 

 

 

The CAL TEMP mode is used to calibrate the platen temperature

4 with an external meter connected to the meter plug inlet on the bottom right side of the unit. Add ± 5°C (± 10°F) .

Repeat Step 2A

A. Press the UP and DOWN Arrow buttons to scroll to CAL TEMP.

B. Press the Steamer LOGO button again to display the current calibration temperature.

C. Press the PRODUCT 2 button to zero any previous calibration offset value. The display will now show the platen temperature without any calibration offset.

CAL TEMP

CAL 245

Factory Presets

Loading factory presets restores the unit to factory settings and voids all user programmed information.

A. During power up, press and hold both PRODUCT 1 and PRODUCT 4 buttons within 3 seconds. The display will flash PRESETS LOADED.

Program mode without storing the change.

CAL 265

CAL 265

 

 

B. Release both buttons.

Default Factory Presets:

 

ON

OFF Cycles

All

1

3

2

presets loaded 129 C

View Firmware Version

Press and hold the Seamer LOGO button first, then press and hold the START button.

The display will show the current firmware version.

. VERS XX.XX

Manual Reset

A hi-limit thermostat will turn off electrical power to the platen and control circuits if the unit overheats.

Turn the unit off and allow to cool (approximately 10-15 minutes).

A manual reset is located on the back of the unit. Once the unit has cooled sufficiently, press the manual reset and restart the unit.

NOTE: If the unit continues to shut-off due to overheating, contact your authorized Prince Castle Service Agency.

Manual Reset

Steamer 625-502revA

3

Printed in USA 0910 © 2003

Page 3
Image 3
Prince Castle 625-A625-A Temperature Adjustment, View Firmware Version, Manual Reset, set temp, Factory Presets, Cal Temp