S t e a m e r 6 2 5 - A
Temperature Adjustment
A. Press and hold the TEMPERATURE button. The display will 1 show the current temperature setting for Celsius (C) or
Fahrenheit (F).
B. While holding the TEMPERATURE button, press the C/F button to change the setting between Fahrenheit and Celsius.
C. Release the TEMPERATURE button to store the new value.
2 | A. Press and hold the Steamer LOGO button first, then |
press and hold TEMPERATURE button for approximately |
6 seconds.
The display will show SET TEMP.
B. Press the Steamer LOGO button again to display the current set temperature.
| 129 C |
|
| 255 F |
|
|
|
|
|
| |
3 | Platen temperature can be set between | ||||
|
|
A. Press the UP or DOWN Arrow buttons to scroll to the desired temperature.
B. Press the Steamer LOGO button to store the desired temperature and exit the SET TEMP mode.
NOTE: Pressing the PRODUCT 3 button at any time exits the Program mode without storing the change.
| TEMP 275 | TEMP 275 |
|
|
|
5 | A. Press the UP or DOWN Arrow buttons until the temperature | |
readout matches the calibration reading. |
B. Press the Steamer LOGO button to store the desired tem- perature and exit CAL TEMP mode.
NOTE: Pressing the Product 3 button at any time exits the
set temp |
| 255 |
|
|
|
|
|
|
|
|
|
The CAL TEMP mode is used to calibrate the platen temperature
4 with an external meter connected to the meter plug inlet on the bottom right side of the unit. Add ± 5°C (± 10°F) .
Repeat Step 2A
A. Press the UP and DOWN Arrow buttons to scroll to CAL TEMP.
B. Press the Steamer LOGO button again to display the current calibration temperature.
C. Press the PRODUCT 2 button to zero any previous calibration offset value. The display will now show the platen temperature without any calibration offset.
CAL TEMP | CAL 245 |
Factory Presets
Loading factory presets restores the unit to factory settings and voids all user programmed information.
A. During power up, press and hold both PRODUCT 1 and PRODUCT 4 buttons within 3 seconds. The display will flash PRESETS LOADED.
Program mode without storing the change.
CAL 265 | CAL 265 |
|
|
B. Release both buttons.
Default Factory Presets:
| ON | OFF Cycles | |
All | 1 | 3 | 2 |
View Firmware Version
Press and hold the Seamer LOGO button first, then press and hold the START button.
The display will show the current firmware version.
. VERS XX.XX
Manual Reset
A
Turn the unit off and allow to cool (approximately
A manual reset is located on the back of the unit. Once the unit has cooled sufficiently, press the manual reset and restart the unit.
NOTE: If the unit continues to
Manual Reset
Steamer | 3 | Printed in USA 0910 © 2003 |