S t e a m e r 6 2 5 - A
Cleaning - Monthly PM Tasks
WARNING
Turn the unit off and unplug the power cord from the electrical recep- tacle. Proceed with caution, unit is still hot!
CAUTION
This unit is not watertight. Do not clean with a water jet/jet spray. Do not immerse the unit in water.
Do not use abrasive materials such as scrapers, steel wool, etc. to clean the spatula or steam chamber.
While wearing protective gloves, remove the top cover by
1 pulling up and off the unit.
Top Cover
The following equipment is required:
•Detergent or Cleaning Solution
•Delimer/Lime Scale Remover (as required)
•Sanitizer
•Clean sanitized towel
•Protective (insulated) gloves
2 While wearing protective gloves:
A.Remove spatula.
B.Remove the top plate by carefully sliding it forward
and out of the unit.
C.Remove the
venturi plate.
Top Plate
Spatula
Venturi Plate
3 | A. Wash top cover, top plate, spatula, and venturi plate in a | 4 | Pour a solution of Delimer into the steam chamber. |
solution of detergent and water. | Let solution soak for at least 15 minutes. |
B.Rinse with clean water, and then sanitize in a solution of sanitizer.
C.Let air dry.
IMPORTANT. It is not recommended
to leave open container of delimer around
5 | A. Clean stem injection ports with a paper clip or small wire. |
B. Rinse with clean water. |
C. Wash all external surfaces of the steamer with a solution of
detergent and water in a spray bottle.
Spray directly onto a clean sanitized towel and wipe the unit clean.
D. Reassemble the unit.
CAUTION
Do not spray directly on the unit or use abrasive cleaners!
Steamer | 7 | Printed in USA 0910 © 2003 |