Procom ML300TGA Operating Your Heater, NON-THERMOSTATMODEL ML300HGA FOR YOUR SAFETY, Pilot

Models: ML300HGA ML300TGA

1 21
Download 21 pages 905 b
Page 12
Image 12
OPERATING YOUR HEATER

OPERATING YOUR HEATER

NON-THERMOSTAT MODEL

ML300HGA

FOR YOUR SAFETY

READ BEFORE LIGHTING

NON-THERMOSTAT MODEL WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance. Do not touch any electric switch, do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone . Follow the gas supplier’s instructions.

if you cannot reach your gas

supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it , call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service

t e c h n i c i a n t o i n s p e c t t h e appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information on the side of heater.

2.Check that gas supply to heater is on.

3.Push in control knob slightly

and turn clockwise READ BEFORE LIGHTING to the OFF position.(see Figure 19)

NOTE: Knob cannot be turned from "PILOT " to "OFF" unless

knob is pushed in slightly. Do not force.

4.Wait five minutes to clear out any gas. Then smell for gas, in-

cluding near the floor. If you smell gas.STOP! Follow "B" in the

safety information on the side of heater. If you don’t smell gas. go to the next step.

5.Push in and turn control knob

counterclockwise LIGHTING to PILOT position. Press in control knob

for five(5) seconds.

Note: You may be running this heater for the first time after hooking up to gas supply. If so, you may need to press in control knob for 30 seconds. This will allow air to bleed from the gas system.

Figure 19 - Control Knob In The OFF Position

Figure 20 - Pilot

6.With control knob pressed in, push down and release the ignitor button. This will light pilot. If needed, keep pressing ignitor button until pilot lights.

7.Keep control knob depressed for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 5,6 and 7.

8.To select the desired heating level, partially press down the control knob slightly and rotate

counterclockwise Figure 19 - Control Knob In The OFF Position . Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position. Do not operate between locked positions.

TO TURN OFF

GAS TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise Figure 20 - Pilot to the OFF position.

2.Turn off all electric power to the appliance if service is to

be performed.

Shutting Off Burner Only (pilot stays lit )

Slightly press in control turn

control knob clockwise

to the

PILOT position.

MANUAL LIGHTING

PROCEDURE

1.Remove lower front panel (see Figure 7 page 7).

2.Follow steps 1 through 5 under Lighting Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow step 8 under Lighting Instructions.

5.Replace lower front panel.

1 2

Page 12
Image 12
Procom Operating Your Heater, NON-THERMOSTATMODEL ML300HGA FOR YOUR SAFETY, Read Before Lighting, Lighting Instructions