TROUBLESHOOTING
Continued
OBSERVED PROBLEM |
| POSSIBLE CAUSE | |
Delayed ignition burner. | 1. | Manifold pressure is too low. | |
| 2. | Burner orifice is clogged. | |
Burner backfiring during combustion. | 1. | Damaged burner. | |
| 2. | Gas regulator | is defective. |
Slight smoke or odor during initial 1. | Residues from | manufacturing | |
operation. |
| processes. |
|
| 2. | Not enough air. |
|
| 3. | Gas regulator is defective. |
REMEDY
1.Contact local gas company.
2.Clean burner (see Cleaning and Maintenance, pages 11).
1.Clean burner orifice (see Cleaning and Maintenance, page 11).
2.Replace gas regulator.
1.Problem will stop after a few hours of operation.
2.Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance, pages 11).
3.Replace gas regulator.
Dark residue on logs or inside of | 1. | Improper log placement. | 1. | Properly locate logs (see Installing | |||
fireplace. |
| 2. | Air holes at burner inlet are blocked. |
| Logs, page 9). |
| |
|
| 3. | Burner flame holes are blocked. | 2. | Clean out air holes at burner inlet. | ||
|
|
|
|
| Periodically | repeat as | needed. |
|
|
|
| 3. | Remove blockage or replace burner. | ||
Heater produces a | clicking/ticking | 1. Metal expanding while heating or | 1. | This is common with most | |||
noise just after burner | is lit or shut off. |
| contracting while cooling. |
| heaters. If | noise | is excessive, |
contact qualified service person.
SPECIFICATIONS
|
| ||
Btu |
| 20000/25000 | 20000/25000 |
Gas Type |
| LP Gas | Natural Gas |
Ignition |
| Piezo | Piezo |
Manifold | Pressure | 8"W.C. | 3"W.C. |
Inlet Gas | Pressure |
|
|
(In. of water)* |
|
| |
Maximum | 14" | 10.5" | |
Minimum | 11" | 5" | |
Dimensions, Inches (H×W×D) |
|
| |
Heater | 33 9/16”×23 1/8”×13 9/16” | 33 9/16”×23 1/8”×13 9/16” | |
Carton | 36 7/8”×26 1/8”×16 1/2” | 36 7/8”×26 1/8”×16 1/2” | |
Weight, lbs |
|
| |
Heater | 73 | 73 | |
Shipping | 84 | 84 | |
*For purposes of input adjustment |
|
|
13