SAFETY
INFORMATION
Continued
15.Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.
16.Operating heater above eleva- tions of 4,500 feet could cause pilot
outage.
17.Do not operate heater if any log is broken. Do not operate heater if a log is chipped
18 . To prevent performance problems, do not use fuel tank of less than 100 lbs. capacity.
LOCAL CODES
lnstall and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code. ANSZ223.1, also known as NFPA54*.
*Available from:
American National Standards lnstitute, lnc.
1430 Broadway New York. NY10018 National Fire Protection Association, lnc. Batterymarch Park Quincy. MA 02269
This heater is designed for vent- free operation. State and local codes in some areas prohibit the use of
UNPACKING
1.Remove top inner pack.
2.Tilt carton so that fireplace is upright.
3.Remove protective side packaging.
4.Slide fireplace out of carton.
5.Remove protective plastic wrap.
6.Remove screen by lifting and then pulling forward.
7.Remove log set by cutting plastic ties.
8.Carefully unwrap logs.
9.Check for any shipping damage. If fireplace or logs are damaged, promptly inform dealer where you bought the fireplace from.
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/ pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
PRODUCT IDENTIFICATION
Decorative Frame
Heater Cabinet
Grill
Logs
Heater Controls
(Inside Door)
3