A C C E S S O R Y M O D E L NFHTX186

INSTALLING BLOWER ACCESSORY BLOWER ACCESSORY MODEL NFHTX186

A C C E S S O R Y M O D E L NFHTX186

Tools required: Philips screwdriver

NOTICE: Shut off gas heater during the following blower installation.

1.From back of heater remove the knock-out center panel with two brackets at the four sides with a Philips head screwdriver (see Figure 1).

2.Attach the two brackets to blower housing using four white screws provided in blower kit (2 for each bracket) (see Figure 3). Tighten screws securely. Then guide the green grounding means wire and downlead of motor through the rubber capped hole.

3.Guide the four strand wire of downlead through the jacket hole. Connect the two yellow leads and the temperature control switch on the temperature controlled bracket togther. Secure the temperature controlled bracket on the reflective panel of firebox using two self- tapping screws(See Figure 4-A).

4.Using the previously removed screws, mount blower assembly to heater by reattaching the knock-out center panel to rear panel. Draw the four strand cable

backward so as to expose the three black, green, white lines on the four strand cable at the back of rear panel. Be sure not to drop the temperature controlled wire off the reflective panel. Connect the green grounding means wire and four strand cable together. Connect the two black motor downleads respectively and the remaining two black and white wires together by the same means (see Figure 4-A). (Note: the three wires must be connected at the rear panel)

5.Using the thread that previously bond the electrical wire to collect and pack the outside connection wire of the cable.

6.Place operation control housing at the bottom of stove. Use two black screws provided in blower kit. Mount blower operation control housing to the bracket at the bottom of stove (see Figure 5).

7.Check to make sure that the power cord is completely clear of blower wheel and there are no foreign objects in blower wheel.

8.Use screws provided in blower kit to assemble the plate which assembled with strain relief bushing and power cord on the knockout center panel.

9.Peel off the backing paper and stick the supplied wiring diagram decal on the back panel as show in Figure 4-B.

10.Plug power cord into a convenient 3- prong grounded wall receptacle near the heater.

WARNING: 1. ELECTRICAL GROUND-

ING INSTRUCTIONS: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.

2.Do not let the wires touch the re- flective panel of the firebox. Feed the wires of the motor and green wire through the hole of the knock-out panel.

11.Using Auto/O/Man switch. Turn blower on and check for operation. Turn on Auto/O/Man switch to the desired position. Man position will remain con- stantly on. Auto position will be con- trolled by the thermostat on fan blower unit. To stop the operation, turn unit switch to the O position.

12.All remaining parts from blower kit may be discarded.