SAFETY INFORMATION WARNINGS

I M P O R TA N T: R e a d

 

t h i s

owner’s manual carefully

and

completely before trying

to

assemble, operate, or

service

this heater. Improper

use of

this heater can cause serious

 

injury

or death from burns,

 

f i r e , e x p l o s i o n ,

e l e c t r i c a l

 

shock,

and carbon

monoxide

 

poisoning.

 

 

 

 

 

 

 

 

DANGER: Carbon

monoxide

 

poisoning may lead to death!

 

 

 

 

 

Carbon

Monoxide

Poisoning:

Early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air immediately! Have heater serviced. Some people are more af- fected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odorless. An odor-making agent is added to Propane/LP gas. The odor helps you detect a Propane/LP gas leak. However, the odor added to Propane/LP gas can fade. Propane/

LP gas may be present even though no odor exists.

Make certain you read and under- stand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this fireplace or its controls can be dangerous.

WARNING: Do not allow fans to blow directly into the heater. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that al- ter burner flame patterns. Altered burner patterns can cause sooting.

WARNING: Do not use acces- sories not approved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects in the fireplace.

Heater becomes very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.

Carefully supervise young children when they are in the room with fireplace.

You must operate this heater with the heater screen in place. Make sure heater screen is in place before running heater.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place Propane/LP supply tank(s) indoors.

3.If you smell gas

Shut off gas supply.

Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.

4.This heater shall not be installed in a bedroom or bathroom.

5. Do not use this heater as a wood-burning heater. Use only the logs provided with the heater.

6.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of heater. After servicing, always replace screen before operating heater.

7.You must operate this heater with the heater screen in place. Make sure heater screen is in place before running heater.

8.This heater is designed to be smokeless. If logs ever appear to

smoke, turn off heater and call a q u a l i f i e d s e r v i c e p e r s o n . Note: During initial operation, slight smoking could occur due to log c u r i n g a n d h e a t e r b u r n i n g manufacturing residues.

9.To prevent the creation of soot, follow the instructions in the Cleaning and Maintenance Section,

pages 11.

10.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

11 . This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See the Air for Combustion and Ventilation Section, pages 4 through 5. If heater keeps shutting off, see Troubleshooting, pages 12 .

12.Do not run heater

Where flammable liquids or vapors are used or stored.

Under dusty conditions.

13.Do not use this heater to cook food or burn paper or other objects.

14.Do not use heater if any part has been under water. lmmediately call a qualified service technician to inspect the room heater and to replace any part of the control system, and any gas control which has been under water.

2

Page 2
Image 2
Procom SL250TYLA-D, SN250TYLA-D installation manual Safety Information Warnings, P O R TA N T R e a d

SL250TYLA-D, SN250TYLA-D specifications

The Procom SL250TYLA-D and SN250TYLA-D are advanced communication solutions designed for professional users who demand reliable and efficient performance in challenging environments. Both models combine cutting-edge technology with robust features, making them ideal for various applications, including public safety, event management, and business communication.

The SL250TYLA-D is particularly known for its standout audio clarity, which ensures that users can communicate seamlessly even in noisy conditions. It boasts a powerful speaker that provides crisp and clear sound, allowing users to stay connected without needing to raise their voice. This robust audio system also incorporates noise-cancellation technology, which filters out unwanted background sounds, enhancing the clarity of communication.

The device features a user-friendly interface, with a large LCD display that provides essential information at a glance. Users can easily navigate through menus and settings, making adjustments on the go. The durable design of the SL250TYLA-D ensures it can withstand the rigors of daily use, with an IP67 rating that makes it resistant to dust and capable of withstanding immersion in water. This durability is complemented by an extended battery life, allowing for all-day use without the need for frequent recharging.

On the other hand, the SN250TYLA-D is specifically designed for versatile communication. It supports multiple frequency bands, allowing it to be used in various communication scenarios, whether in urban settings or remote areas. The device is equipped with digital encryption features, ensuring secure communications that protect sensitive information from eavesdropping or interception.

In terms of connectivity, both models support Bluetooth functionality, allowing users to connect to headsets and other devices, enhancing hands-free communication. They also feature a variety of programmable buttons that can be customized to suit the user's needs, enabling quick access to frequently used functions.

Another significant characteristic of the SL250TYLA-D and SN250TYLA-D is their compatibility with other Procom accessories, such as external antennas and chargers, allowing for a customizable communication setup. These models are designed for ease of use, making them an excellent choice for teams that need reliable and immediate communication in dynamic environments.

Overall, the Procom SL250TYLA-D and SN250TYLA-D stand out for their exceptional audio quality, durable design, advanced security features, and user-friendly interfaces. They represent a solid investment for organizations that prioritize effective communication and operational efficiency in their daily operations.