INSTALLATION
Minimum Wall and Ceiling Clearances
(see Figure 4)
A. Clearances from outermost point of fireplace top to any combustible side wall should not be less than 12 inches. B. Clearances from the fireplace top to the ceiling should not be less than 48 inches.
IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 4. Measure from outermost point of fire- place top.

INSTALLATION

CHECK GAS TYPE NOTICE: This heater is in- tended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system's circulating blower while using heater. This will help circulate the heat throughout the house . In the event of a power outage, you can use this heater as your primary heat source.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS WARNING: A qualified service person must install heater. Follow all local codes.

Manual background WARNING: Never install the heater:

in a bedroom or bathroom in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater in high traffic areas

in windy or drafty areas

Manual background CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist,may discolor walls.

Manual background WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining side and back walls.

6” Minimum

6” min

6” min

Figure 4 -Minimum Clearance to Wall IMPORTANT: Vent-free heaters add

moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew. See Air for Combustion and Ventilation, pages 4 through 5.

CHECK GAS TYPE

Use only the type of gas indicated on the plate. If your gas supply can not meet that requirement, do not install heater. Call dealer where you bought heater from for proper heater type.

CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only) Carefully follow the instructions below. This fireplace is a freestanding unit designed to set directly on the floor.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vaporis a by-product of gas combustion.An unvented room heater productes approximately one (1) ounce (30ml) of wter for every 1,000 BTU’s (.3KW’s) of gas input per hour.

Unvented room heaters are remommended as supplemental heat (a room) rather than a primary heat source (an entire house) .In most supplemental heat application, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experience during cold weather.

The following steps will help insure that water vapor does not become a problem.

1.Be sure the heater is sized properly for the application, including ample combusion air and circulation air.

2.If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air.

3.Do not use an unvented room heater as the primary heat source.

6