Profoto D1 250 Air, D1 1000 Air, D1 500 Air Maintenance, Changing flash tube and/or modeling lamp

Models: D1 500 D1 250 Air D1 1000 Air D1 500 Air D1 250

1 24
Download 24 pages 25.32 Kb
Page 17
Image 17

Maintenance

Changing flash tube and/or modeling lamp

1.Ensure that the D1 unit is turned off and that the power cable is not connected.

2.If the unit has been in use, wait five minutes to allow the unit to be fully discharged.

3.Gently remove the frosted glass plate.

4.Change the flash tube:

Unlock the flash tube trigger by unfolding the stainless steel ribbons around the clasp.

Grasp the flash tube in the bottom and pull it straight out of the socket.

When inserting the new flash tube, ensure that the trigger connection clasps properly around the flash tube.

Lock the flash tube trigger by folding the stainless steel ribbons around the clasp.

5.Change the modeling lamp:

Pull the lamp straight out of the socket.

Insert a new modeling lamp, straight into the socket. Do not touch the lamp with bare hands.

6.Carefully fit the glass plate in place, with the frosted side inwards. Make sure that the safety pins fit properly around the glass plate.

Profoto D1

17

Clasp

Flash tube

Modeling lamp

www.profoto.com

Page 17
Image 17
Profoto D1 250 Air, D1 1000 Air manual Maintenance, Changing flash tube and/or modeling lamp, Clasp Flash tube Modeling lamp