PVI Industries manual 11.5To View The Setpoint, 11.6To Change The Setpoint, PV500-47C06/12

Models: PV500-47C

1 40
Download 40 pages 9.54 Kb
Page 22
Image 22

11.5To View The Setpoint

Push and release the SET key to see the set point value.

To return to normal display, press SET + UP or wait 15 seconds without pressing any key.

11.6To Change The Setpoint

Push the SET key. The upper display will show the “St1” parameter name, while the lower display will show its value.

Use the UP or DOWN key to cycle through the parameter names.

Push the SET key to modify a parameter value. The value starts flashing in the lower display.

To change it push the UP or DOWN keys. Push the SET key again to confirm the value and pass to the setting of next set point.

Repeat the operations described at points 3, 4, 5.

To Exit: press SET + UP or wait 15 seconds without pressing any key

NOTE: Each point has a time out of 15 seconds. If any key is pushed within 15 seconds the controller exits the set points programming procedure.

NOTE: The set value is stored even when the procedure is exited by waiting the time-out to expire.

11.7To Change Other Parameters

Push the SET and DOWN arrow simultaneously for 3 seconds.

Select the required parameter. The name of the parameter is on the upper display; its value is on the lower display.

Press the SET key: the value of the parameter will start blinking.

Use UP or DOWN to change the value.

Press SET to store the new value and move to the following parameter.

To Exit: Press SET + UP or wait 15s without pressing a key.