and Welcome to the Quadra-Fire Family!
Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a
This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation of our stoves, inserts and fi replaces. And yet we are
meticulously fabricated and gold and nickel surfaces are
We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
LOCATION: HANGING ON A CHAIN ON BACK OF APPLIANCE
| Portland |
|
| MODEL / MODÈLE: |
|
|
| Serial No / Numéro du |
|
|
| Report No. / Rapport Numéro | VENTED GAS | FIREPLACE HEATER / NOT FOR USE WITH | SOLID FUEL |
|
| 1445 North HIghway | |||
| FOURNAISE AU GAZ AVEC VENTILATIONNE PAS UTILISER AVEC LE |
|
| |||||||
|
|
| Colville, WA 99114 | |||||||
|
|
| COMBUSTIBLE SOLIDE |
|
|
| www.quadrafire.com | |||
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
APPROVED FOR CANADA AND USA TO: |
|
| APPROUVÉ POUR LE CANADA ET LES |
ANSI
“Gas Fired Appliances for use at High Altitudes.” This appliance is manufactured for operation with Natural | Appliances for use at High Altitudes”. Cet appareil est manufacturé pour l’opération avec le Gaz Naturel. Pour une | ||||||
Gas. For conversion to propane Manufacturer’s instructions must be used. This appliance may be installed | conversion au gaz propane Manufacturier instructions doivent être utilisées. Cet appareil peut être utilisé dans une | ||||||
in a bedroom or bedsitting room; in Canada remote thermostat installation is required. Blower is optional. | chambre à coucher ou salle de séjour; au Canada, l’installation d’un thermostat à distance est exigée. Ventilateur | ||||||
Order Part | optionnel, Pièce | ||||||
|
|
|
|
| de l'appareil. |
|
|
| FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE |
| Thermal Efficiency / Efficacité Thermique* | 76.93% NG (No blower / Sans ventilateur allumé) |
| ||
| Blower Electrical Rating / Evaluation du Ventilateur |
|
|
| 78.19% LP (No blower / Sans ventilateur allumé) |
| |
| 115 V, .55 Amps, 60 Hz, 150 Watts |
|
|
|
| *With Maximum horizontal length. / Avec longueur horizontale maximum |
|
|
|
|
|
|
| ||
|
| For use with Natural Gas | For use with Propane |
|
| ||
|
| Usage au gaz naturel | Usage au gaz propane |
|
| ||
|
|
|
|
|
| ||
Input Rate on “HI” (BTU/Hr) | 17,000 |
|
| 17,000 | Puissance Évaluée à “HI” (BTU/Hr) | ||
Input Rate on “LO” (BTU/Hr) | 12,000 |
|
| 13,000 | Puissance Évaluée à “LO” (BTU/Hr) | ||
Maximum Output (BTU/Hr)** | 14,500 |
|
| 13,500 | Puissance Maximum (BTU/Hr** | ||
Main Burner Orifice | 49 |
|
| 56 | Orifice du Brûleur Principal | ||
Minimum Inlet Pressure (Inches W.C.) | 4.5” |
|
| 11” | Pression Minimum de la Valve (pouces W.C.) | ||
Maximum Inlet Pressure (Inches W.C.) | 7.0” |
|
| 14” | Pression Maximum de la Valve (pouces W.C.) | ||
Manifold Pressure on “HI” (Inches W.C.) | 3.5” |
|
| 10” | Pression du Collecteur d’ Échappement à “HI” (pouces W.C.) | ||
**Max Venting, Blower On |
|
|
|
| **Ventilation Maximum, Ventilateur Allumé |
This appliance equipped for altitudes
Serial Number
Model Name
Test Lab & Report No.
F
B
A A E
"A" measurement is from stove top, not side
A.Side of stove top to side wall
B.Rear of stove to back wall
C.Corner of stove top to side
C.Corner of stove top to side
D.Minimum Alcove Height
E.Maximum Alcove Depth
F.Minimum Alcove Width
G.Mantle Clearance from stove top
H.Top of Stove to Alcove Ceiling
C
Left
C
Right
G
D
6 in. (15cm)
2 in. (5cm)
2 in. (5cm)
2 in. (5cm)
43 in. (109cm)
36 in. (91cm)
30 in. (76cm)
H
AA
Du coté du poêle au coté du mur Le contrôle arrière au mur arrière
Du coin arrière du poêle au mur de coté gauche
Du coin du dessus du poêle au mur de coté droit (acces a la valve) Hauteur minimum du plancher au plafond
Profondeur maximum de l'alcove Largeur minimum de l'alcove Espace libre du poêle au manteau Distance entre le haut du poêle et le plafond
HEARTH: A
CHEMINÉE: Un coussinet
|
| Date of Manufacture / Date du Manufacturier |
|
|
|
|
|
| ||||
2008 2009 2010 Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
|
|
| Made in U.S.A. / Fait Aux |
|
|
|
| ||||||
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ÉTIQUETTE |
|
|
|
Manufactured Date
Page 2 | August 1, 2008 |