Quadra-Fire GARNET-D-CWL 4Termination Locations, A. Vent Termination Minimum Clearances, 3.25

Models: GARNET-D-CSB GARNET-D-CWL GARNET-MBK GARNET-D-MBK GARNET-D-PMH

1 56
Download 56 pages 40.99 Kb
Page 8
Image 8
4Termination Locations

4Termination Locations

A. Vent Termination Minimum Clearances

A. Vent Termination Minimum Clearances WARNING

Fire Risk.

Explosion Risk.

Maintain vent clearance to combustibles as specifi ed.

• Do not pack air space with insulation or other materials.

Failure to keep insulation or other materials away from vent pipe may cause fi re.

Measure vertical clearances from this surface.

2FT.

MIN.

GAS DIRECT VENT

TERMINATION CAP

HORIZONTAL

OVERHANG

20 INCHES MIN.

VERTICAL

 

WALL

LOWEST

DISCHARGE

OPENING

X

12

Roof Pitch ROOF PITCH

IS X/ 12

H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING

Measure horizontal clearances from this surface. (See Figure 4.4 for specifi c clearances.)

Figure 4.1 Termination Clearances

GAS, WOOD OR FUEL

 

OIL TERMINATION

B

 

 

 

 

 

GAS

 

 

 

 

 

 

 

 

 

 

 

C

TERMINATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H (Min.) Ft.A3.25

 

Gas

Wood & Fuel Oil

Comments

 

Termination

Termination

 

 

 

 

 

 

A

6 in.

20 in. min.

Horizontal distance between terminations

 

 

 

 

B

20 in.

24 in. min.

Distance to perpendicular wall

 

 

 

 

C

18 in.

18 in.

Vertical distance between terminations

 

 

 

 

Roof Pitch

H (Min.) Ft.

Flat to 6/12

1.0*

Over 6/12 to .......................................................7/12

1.25*

Over 7/12 to 8/12

1.5*

Over 8/12 to 9/12

2.0*

Over 9/12 to 10/12

2.5*

Over 10/12 to 11/12

3.25

Over 11/12 to 12/12

4.0

Over 12/12 to 14/12

5.0

Over 14/12 to 16/12

6.0

Over 16/12 to 18/12

7.0

Over 18/12 to 20/12

7.5

Over 20/12 to 21/12

8.0

* 3 foot minimum in snow regions

Figure 4.3 Minimum Height from Roof to Lowest Discharge Opening

Figure 4.3 specifi es minimum vent heights for various pitched roofs.

Figure 4.2 Multiple Vertical Termination

Page 8

Quadra-Fire · Garnet-T · 7016-127F

August 1, 2008

Page 8
Image 8
Quadra-Fire GARNET-D-CWL 4Termination Locations, A. Vent Termination Minimum Clearances, Roof Pitch, H Min. Ft, 3.25