V I I . O P E R A T I O N
Speed Keys
There are two keys that control the speed. Press the hare key to increase the speed. Press the tortoise key to decrease the speed. The speed setting is displayed on the speed indicator. If your power chair was programmed with a drive profile, contact your Quantum Rehab Specialist for more information.
NOTE: We recommend that the first few times you operate your power chair, you set the speed to the slowest setting until you become familiar with your new power chair.
Off-board Charger/Programming Socket
You may use an
WARNING! Only chargers with Neutrik NC3MX plugs should be connected to the
NOTE: The socket may also be used for reprogramming the FLIGHT. Contact your Quantum Rehab Special- ist for more information.
Sleep Mode (If Enabled)
The power chair controller features a sleep mode. Sleep mode is a
Error Codes
The battery condition meter will flash error codes when the FLIGHT controller detects an abnormal condition in the electrical system. All of the battery condition meter LEDs will flash a number of times quickly, then pause, then flash again. The battery condition meter will continue to flash the error codes until the problem is fixed. The table below identifies the individual error codes. If any of these error codes persist, contact your Quantum Rehab Specialist.
Error Code | Probable Cause | Possible Solution |
1 | Possible stall timeout or user error | Release the joystick |
|
|
|
2 | Battery Fault | Check the batteries and cables. Try to charge the |
|
| batteries. The batteries may need to be replaced. |
|
|
|
3 | Left Motor Fault | Check the left motor, connections, and cabling. |
|
|
|
4 | Right Motor Fault | Check the right motor, connections, and cabling. |
|
|
|
5 | Left Park Brake Fault | Check the left park brake, connections, and cabling. |
|
|
|
6 | Right Park Brake Fault | Check the right park brake, connections, and cabling. |
|
|
|
7 | FLIGHT Controller Module Fault | Check the communications connections and wiring. |
|
|
|
8 | FLIGHT Power Module Fault | Check the communications connections and wiring. |
|
|
|
9 | FLIGHT Communications Fault | Check the communications connections and wiring. |
|
|
|
10 | Unknown Fault | Contact your Quantum Rehab Specialist. |
|
|
|
11 | Incompatible Controller Fault | Contact your Quantum Rehab Specialist. |
|
|
|
Quantum 610 | www.quantumrehab.com | 37 |