Quartz QZ3111 Troubleshooting guide, Symptom, Action, Quartz Thermo installation guide, markings

Models: QZ3111

1 16
Download 16 pages 50.84 Kb
Page 14
Image 14

Troubleshooting guide

Symptom

Possible cause

Action

 

 

 

 

 

 

Water output is either

Reversed inlet supplies
Check that the supplies
all hot or all cold,

 

correspond with the inlet
or cold only

 

markings

 

 

 

 

 

 

Water output is not hot
The temperature of the hot
The cylinder temperature
enough
water cylinder is too low
should be at least 15˚c

 

 

hotter than the blend

 

Water flow through the
Check the flow rate

 

appliance is too fast
recommendations with

 

 

the heater manufacturer

 

 

 

 

 

 

Flow rate is poor and
Airlock in the water
Check that the pipe work
water temperature is low
supply
is laid in accordance with

 

 

the correct practices,

 

 

paying particular attention

 

 

to potential air-traps

 

 

 

 

 

 

Water temperature
Cold water pressure is
If the static water pressure
regularly swings between
too high
exceeds 7 bar (100 psi)
hot and cold

 

install a pressure reducing

 

 

valve (PRV) in accordance

 

 

with the installation guide

 

The flow regulator has
Fit the flow regulator

 

not been fitted

 

 

 

 

 

 

 

Poor flow rate
Twisted hose
Check and clear as

 

Debris in shower head
necessary

 

Debris in filters

 

 

Debris in cold inlet flow

 

 

regulator

 

 

 

 

Quartz Thermo installation guide

 

page 14

 

 

 

Page 14
Image 14
Quartz QZ3111 manual Troubleshooting guide, Symptom, Action, Quartz Thermo installation guide, Possible cause, or cold only