ASM-60 Installation and Operation Manual Chapter 2 Installation and Setup
Installation and Setup 2-5
Connecting the Power
Before switching on this unit and connecting any other cable, the protective
earth terminals of this unit must be connected to the protective ground
conductor of the power cord. If you are using an extension cord (power cable)
make sure it is grounded as well.
Any interruption of the protective (grounding) conductor (inside or outside the
instrument) or disconnecting of the protective earth terminal can make this
unit dangerous. Intentional interruption is prohibited.
The line fuse is located in an integral-type fuse holder located on the rear
panel. Make sure that only fuses of the required rating, as marked on the rear
panel, are used for replacement. Do not use repaired fuses or short-circuit the
fuse holder. Always disconnect the mains cable before removing or replacing
the fuse. Whenever it is likely that the fuse protection has been damaged,
make the unit inoperative and secure it against unintended operation.
AC power is supplied to the ASM-60 modem through a standard 3-prong plug
with an integral fuse holder (see Figure 2-1).
AC power should be supplied through the 5 ft (1.5m) standard power cable
terminated by a standard 3-prong plug. The cable is provided with the unit.
To connect the AC power:
1. Connect the power cable to the power connector on the ASM-60 rear panel.
2. Connect the power cable to the mains outlet.
The unit will be turned on automatically upon connection to the mains.
Warning