Technical Data

Technical Data

This cooker is designed for use on either :-

NATURAL GAS (Cat I2H ) at 20mbar or

LP GAS (Cat I3+ ) Butane 29mbar / Propane 37mbar.

NB: THE NATURAL GAS AND LP GAS VERSIONS OF THESE COOKERS ARE DIFFERENT MODELS AND CANNOT BE CONVERTED FROM ONE GAS FAMILY TO THE OTHER.

INSTALLER: Please leave these instructions with the User.

DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.

Country of Destination: GB/IE

 

Gas

 

Electric

Natural Gas

20mbar

220 - 240V 50Hz

Butane

29mbar

 

Propane

37mbar

 

(See appliance data badge for test pressures)

Dimensions

Overall height

minimum 893mm maximum 920mm

Overall width

900mm See ‘Positioning of Cooker’

Overall depth

648mm

Space for fixing

See ‘Positioning of Cooker’

Minimum space above hotplate

650mm

Connections

Gas:

Electric

Rp 1/2 at rear right-hand side

220 - 240V 50Hz

Ratings

 

Natural Gas

L.P. Gas

 

 

 

Injector

 

Injector

Hotplate

 

 

 

 

Wok burner

3.5kW

internal 80

3.5kW(246g/h)

internal 54

 

 

external 129

 

external 77

Large Burner

3.0kW

134

3.0kW (210g/h)

87

Medium Burners

1.7kW

109

1.7kW (119g/h)

68

Small Burner

1.0kW

75

1.0kW (70g/h)

51

Main Oven

3.2kW

237

2.9kW (224g/h)

85

Tall Oven (electric)

2.5kW

 

2.5kW

 

Grill

2.73kW

190

2.73kW (192g/h)

85

Gas burner inputs based on Gross Calorific Value

Total electrical load 2.6kW approx.