Step 3

16

Type 150/400 Autopilot System: Installation Guide

Table 3-1: Recommended power supply cable sizes (stranded cables)

Cable length

Cable gauge

Copper area

(distribution panel to course computer)

(AWG)

(mm2)

Type 1 drive 12/24 V;

 

 

I/O drive; CR pump solenoids*

 

2.5 mm2

up to 3m (10ft)

14 AWG

up to 5m (16ft)

12 AWG

4 mm2

up to 7m (23ft)

10 AWG

6 mm2

up to 10m (32ft)

8 AWG

10 mm2

up to 16m (52ft)

6 AWG

16 mm2

Type 2 drive 12 V

 

6 mm2

up to 5m (16ft)

10 AWG

up to 7m (23ft)

8 AWG

10 mm2

up to 16m (52ft)

6 AWG

16 mm2

Type 2 drive 24 V

 

4 mm2

up to 3m (10ft)

12 AWG

up to 5m (16ft)

10 AWG

6 mm2

up to 10m (32ft)

8 AWG

10 mm2

up to 16m (52ft)

6 AWG

16 mm2

Type 3 drive 12 V

 

10 mm2

up to 5m (16ft)

8 AWG

up to 7m (23ft)

6 AWG

16 mm2

up to 16m (52ft)

4 AWG

25 mm2

Type 3 drive 24 V

 

6 mm2

up to 5m (16ft)

10 AWG

up to 7m (23ft)

8 AWG

10 mm2

up to 16m (52ft)

6 AWG

16 mm2

Table 3-2: Recommended power cable fuse and circuit breaker sizes

Drive unit

Fuse (Amps)

Thermal over-current

circuit breaker (Amps)

 

 

 

 

 

Rotary, linear, hydraulic pump,

 

 

hydraulic linear

 

 

 

 

 

Type 1: 12 V and 24 V

25 A

20 A

Type 2: 12 V

40 A

30 A

Type 2: 24 V

30 A

30 A

Type 3: 12 V and 24 V

40 A

30 A

 

 

 

I/O drive

15 A

10 A

 

 

 

CR pump solenoids*

10 A

10 A

*These specifications apply to the cabling for CR pump solenoids. Power the CR pump motor separately, as specified in the CR pump installation guide.

Page 24
Image 24
Raymarine 150/400 manual Cable length Cable gauge Copper area, Type 1 drive 12/24 Drive CR pump solenoids, Type 2 drive 12