BoardTemp

(1)

-

Degrees

Celsius

22

BoardTemp

(2)

-

Degrees

Celsius

27

SwitchDiagnosticsStatusPassed

SwitchTemperatureStatusNormal

3.If the correct firmware version is loaded but not active, use the fallback command to make it active.

4.If the correct firmware version is not loaded, refer to the SANbox2 Fibre Channel Switch Installer’s/User’s Manual information on how to install firmware.

Port and switch configuration

You must ensure that all the Fibre Channel ports are correctly configured for operation with Grass Valley equipment. With these settings, you can use any port in a SCSI or IP fabric without any further configuration.

1.In administrator mode type the following command at the prompt to enter the configuration mode:

sb5_8port (admin) #> config edit

2.In configuration mode, type the following command at the prompt to view the configuration of all the ports on the switch.

sb5_8port (admin-config) #> set config ports

3. Modify the settings as needed. The following example shows the required settings.

A list of attributes with formatting and current values for the port specified at the command line or port #0 will follow.

Each value that is changed will be set for ALL PORTS.

If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key to do so.

Configuring ALL ports (displaying values from port number: 0)

----------------------------------------------------------

AdminState

(1=Online, 2=Offline, 3=Diagnostics, 4=Down)

[Online]

LinkSpeed

(1=1Gb/s, 2=2Gb/s, 3=Auto)

[Auto]

PortType

(TL /

GL / G / F / FL / Donor)

[GL]

TLPortMode

(1=TLTargetMode, 2=TLInitiatorMode)

[TLTargetMode]

ISLSecurity

(Any / Ours / None)

[Any]

ALFairness

(True

/ False)

[False]

ARB_FF

(True

/ False)

[False]

InteropCredit

(decimal value, 0-255)

[0]

ExtCredit

(dec value, increments of 11, non-loop only)

[0]

FANEnable

(True

/ False)

[True]

LCFEnable

(True

/ False)

[False]

MFSEnable

(True

/ False)

[True]

MFS_TOV

(decimal value, 10-20480 msec)

[10]

MSEnable

(True

/ False)

[True]

NoClose

(True

/ False)

[False]

16

Fibre Channel Switch

16 April, 2003

Page 16
Image 16