F18

F19

F20

English

9. Maintenance

PROCEDURES TO BE PERFORMED AFTER

EVERY 100 HOURS OF USE

1.Remove the muffler, insert a screwdriver into the vent, and wipe away any carbon buildup. Wipe away any carbon buildup on the muffler exhaust vent and cylinder exhaust port at the same time.

2.Tighten all screws, bolts, and fittings.

AIR INLET NET

IMPORTANT

Blowing air is taken in from the air inlet net. When air flow has dropped down during operation, stop the engine and inspect the air inlet net for blocking by obstacles.

Note that failure to remove any such obstacles may result in the engine becoming overheated and damaged.

(1) Net

WARNING

Never use the blower without the net of the blower. Before each use, check that the net is attached in place and is free from any damage.

IGNITION COIL AIR GAP INSPECTION

If the gap is out of standard or when installing the coil or rotor, adjust the air gap between the ignition coil and the iron core of the rotor.

Air Gap:

0.3~ 0.4mm 0.012 ~ 0.016"

(1)Rotor

(2)Ignition coil

SHOLDER STRAP

If the shoulder strap is damaged it may break during use, thus causing the product to fall and resulting in personal injury. Follow the instructions below to

40

Page 40
Image 40
RedMax EBZ3000RH-CA manual Procedures to be Performed After Every 100 Hours of USE, AIR Inlet NET, Sholder Strap