Regency C33-NG3 Clearances To Combustibles, Optional Fan Installation, Diagram Diagram

Models: C33-NG3 C33-LP3

1 28
Download 28 pages 63.1 Kb
Page 7
Image 7
CLEARANCES TO

INSTALLATION

This includes:

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label) after burning appliance for 15 minutes.

2)If required, adjusting the primary air to ensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

3)Check for proper draft.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

CLEARANCES TO

COMBUSTIBLES

The clearances listed below are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. The far- thest distance is correct if the two clearances do not coincide. For example, if the appliance is set as indicated in one of the diagrams but the back wall is too close, move the stove until the correct clearance to the back wall is obtained.

This unit can be installed on a solid combustible surface like a wood fl oor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with the unit) is installed.

OPTIONAL FAN

INSTALLATION

Important: Disconnect the power supply before installation or serv- icing.

For pedestal unit: To install the fan in an in- stalled stove-access from front through the pedestal by following the directions below. If the stove is not installed - access through rear and follow steps 4 to 17.

For leg unit: remove 7 screws, remove bottom access panel and install fan assembly and follow steps 4 to 17.

1)Open pedestal door and remove door cover plate by removing 4 screws. See diagram 1.

4)Screw the four 8-32 x 3/4 screws provided into the nutserts as shown in diagram 3. Do not tighten screws.

5)Push all the fan wires through the hole on the fan assembly. See diagram 2

.

6)Putpowercord(shownindiagram3)through the hole and pull through to front of unit for easier installation of ground wire.

7)Place fan assembly partially in door cover plate hole. See diagram 2.

8)Attach the 2 ground wires (green) to the ground lug as per diagram 2.

Note:Ground lug is located on the bottom of the fan assembly. See diagram 2.

This appliance may be installed only with the clearances as shown in the situations pictured. Do not combine clearances from one type of installation with another in order to achieve closer clearances. Use the minimum clearances shown in the diagrams. Alcove installations are approved, as long as side wall clearances are maintained.

C33-3 Clearances to Combustibles

A

Side Wall to Unit

10" / 250 mm

B

Back Wall to Unit

6" / 150 mm

E

Side Wall to Unit

1.5" / 38 mm

 

 

 

C33-3 Reference Dimensions

 

 

to Flue Centerline

C

Back Wall

11-1/2"/ 292 mm

D

Side Wall

22" / 559 mm

F

Side Wall

13" / 330 mm

Minimum ceiling height is 36" / 914 mm from

Diagram 3

9) Lift the fan assembly in through the pedestal and up through the cut out as shown in diagrams 3 and 4.

10) Put the insulation gasket on the back of the fan. Line up the keyhole slots with the matching screws and pull back slightly to lock into place. While holding fan assembly in place, tighten screws.

Diagram 1

2)Remove valve cover plate by removing 2

screws.

3) Remove wire from piezo ignitor.

Diagram 4

Diagram 2

Regency® CLASSIC C33-3 Freestanding Gas Stove

7

Page 7
Image 7
Regency C33-NG3, C33-LP3 installation manual Clearances To Combustibles, Optional Fan Installation, Diagram Diagram