SAFETY LABEL FOR S2400M

SAFETY LABEL

This is a copy of the label that accompanies each Regency Medium Freestanding Step Stove (S2400M). We have printed a copy of the contents here for your review.

NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

SAFETY LABEL FOR S2400M

LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO DO NOT REMOVE THIS LABEL

SUITABLE FOR MOBILE HOME INSTALLATION

 

245

 

 

 

 

MODEL: REGENCY MEDIUM FREESTANDING STEP STOVE - S2400M

TESTED TO: UL1482 / ULC S627 / UL 737
REPORT NO: 219-S-02-2

THE S2400M MEETS UL737 STANDARD FOR FIREPLACE STOVES WHEN A FIRESCREEN IS PROVIDED.

 

 

INSTALLAND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.

 

 

 

 

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.

 

 

USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT

 

 

FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.

 

 

SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A

 

 

CHIMNEY THROUGHACOMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE

S2400M

WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

OCT NOV DECSUITABLE FOR MOBILE HOME INSTALLATION

S2400M MINIMUM CLEARANCES

TO COMBUSTIBLE MATERIALS

 

 

 

 

 

 

MEASURE

 

 

 

 

FLUE

FROM

 

HEATER

 

 

CENTER-LINE

RESIDENTIAL INSTALLATION USING

 

 

SINGLE WALL CONNECTOR

SIDEWALL

 

A 406 mm / 16 in

 

 

D 711 mm / 28 in

 

 

 

BACKWALL

 

B 280 mm / 11 in

 

 

E 444 mm / 17.5 in

CORNER

 

C 152 mm / 6 in

 

 

F 444 mm / 17.5 in

INSTALLATION USING LISTED DOUBLE WALL

 

CONNECTOR - MOBILE HOME

SIDEWALL

 

A 380 mm / 15 in

 

 

D 685 mm / 27 in

 

 

BACKWALL

 

B 140 mm / 5.5 in

 

 

E 304 mm / 12 in

CORNER

 

C 102 mm / 4 in

 

 

F 393 mm / 15.5 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL

 

A 380 mm / 15 in

 

 

D 685 mm / 27 in

 

 

 

BACKWALL

 

B 140 mm / 5.5 in

 

 

E 304 mm / 12 in

CORNER

 

C 102 mm / 4 in

 

 

F 393 mm / 15.5 in

 

 

 

 

 

 

INSTALLATION USING LISTED DOUBLE WALL

 

 

CONNECTOR - ALCOVE

SIDEWALL

 

G 380 mm / 15 in

 

 

I 685 mm / 27 in

 

 

 

BACKWALL

 

H 140 mm / 5.5in

 

 

J 304 mm / 12 in

 

 

 

 

 

 

MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT

MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.

MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"

THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.

 

FLOOR

BACK M

 

 

 

O

L

PROTECTION*

SIDE

 

 

 

DE

K

405 mm / 16 in

 

 

SI

L

150 mm / 6 in

 

 

 

M 150 mm / 6 in

 

 

 

K FRONT

*In Canada, ßoor protection must extend 18" (450mm) to the front and 8" (200mm) to each side and back of the stove.

MAR APR MAY JUN JUL AUG SEPTTESTED TO: UL1482 / ULC S627 / UL 737

FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED.

IF INSTALLED IN A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. WHEN OPERATED WITH DOORS OPEN THE MANUFACTURER SUPPLIED SCREEN MUST BE USED. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.

OPTIONAL COMPONENT: FAN (846-515), ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, SCREEN DOOR (846-101)

DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.

COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR

IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM: SECURITY MODEL S2100, ICC EXCEL 2100, SELKIRK SENTINAL CF.

IN USA: LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL-FAB TEMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.

MANUFACTURED BY: FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 VENTURE ST.

DELTA, BC V4G 1H4

MADE IN CANADA

UNITED STATES ENVIRONMENTAL

CERTIFIED TO COMPLY WITH JULY 1990

PROTECTION AGENCY

PARTICULATE EMISSION STANDARDS.

 

 

 

CAUTION

HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS. 918-203b

rev. 11/05

JAN FEBREPORT NO: 219-S-02-2