![](/images/new-backgrounds/1013034/1303431x1.webp)
INSTALLATION
LISTED COMPONENTS
FOR MOBILE HOME
INSTALLATION
The Regency F2400M and S2400M Freestand- ing pedestal units are approved for installation in a Mobile Home if one of the following pipe systems is used.
U.S. Installation*
METALBESTOS SSII
Qty. Part # | Description | |
1 | Connector Kit | |
1 | 6TMH | Shield/Support |
1 | Flashing | |
1 | Chimney Length | |
1 | Chimney Length | |
1 | Rain Cap | |
| ||
Qty.Part # | Description |
SIMPSON
Qty.Part # | Description |
1 6DVL8693 | Connector Kit |
1
ICC EXCEL 2100
Qty.Part # | Description |
16CL48 48" Chimney length (also in
|
| 12", 18", 24" lengths. |
1 | 6RC | Rain Cap |
1 | 6RCS | Spark Screen (for rain cap) |
16RDS/SQS Round/Square support box
1 | 6VF | Flashing |
1 | 6UBA | "Ultrablack" Close Clearance |
|
| Connector |
Canadian Installations*
SECURITY S2100 (see above for details)
ICC EXCEL 2100 (see above for details)
SELKIRK SENTINAL CF
Slide the tube into the left hand side, as far as possible and then bring it back into the hole on the right hand side until it locks into position. If the tube will not slide in easily, simply use a pair of vise grips or pliers and tap it into place with a hammer. A tighter fit will ensure the tube will not move when the unit is burning.
2)Slide the left baffle over the air tubes from the front and then push it to the back.
Side View
1 | Connector | |
1 | CSB | Shield/Support |
1 | RRS | Radiation Shield |
1 | LFR03 | Flashing |
1 | SL3 | Chimney Length |
1 | SL1 | Chimney Length |
1 | RCSA | Rain Cap |
SECURITY ASHT | ||
Qty.Part # | Description | |
1 | Connector Kit | |
1 | 6SS | Shield/Support |
1 | 6FAMH | Flashing |
1 | 6L3 | Chimney Length |
1 | 6L1 | Chimney Length |
1 | CPE | Rain Cap |
*The use of alternate pitch flashings, support | 3) Tilt the left baffle up on top of the side chan- |
box extensions, additional chimney lengths, | nel and it will leave enough room to position |
and additional chimney bracing, may be used | the right baffle in the same manner as Step |
on each of the previously listed systems. These | 1) above. Then reposition the left baffle flat |
parts though must be from the same system | on the air tubes. |
as listed, and must be a similar and/or compli- |
|
mentary part. |
|
CAUTION:At no time use unlabelled parts, or substitute parts made for another chimney system.
Install as per chimney manufacturer's instal- lation instructions.
Front View
SECURITY S2100
Qty.Part # | Description | |
1 | Connector Kit | |
1 | 6XSF | Support |
1 | 6XFA | Flashing |
1 | 6XL3 | Chimney Length |
1 | 6XL18 | Chimney Length |
1 | 6XCPE | Rain Cap |
Qty.Part # | Description | |
1 | 6DWBK | Connector |
1 | 6TGRS | Roof Support |
1 | 6TGG36 | Chimney Length |
1 | 6TGG12 | Chimney Length |
1 | 6TGF | Flashing |
1 | 6TGC | Rain Cap |
|
| |
Qty.Part # | Description | |
1 | 6DCC | Connector |
1
|
| |
1 | 6F | Flashing |
1 | Chimney Length | |
1 | Chimney Length | |
1 | Rain Cap |
FLUE BAFFLE &
SECONDARY AIR TUBE
INSTALLATION
The flue baffle system located in the upper area of the firebox is removable to make cleaning your chimney system easier. The baffles must be installed prior to your first fire. Smoke spillage and draft problems may occur if the baffles are improperly positioned. Check the position of the baffles on a regular basis as they can be dislodged if too much fuel is forced into the firebox.
Freestanding Stove
F2400M
The unit arrives with the 2 baffles on the floor of the firebox.
1)If all 4 air tubes are installed continue on to Step 2), if not, follow the instructions below. Install the air tube into the holes in the side channels. The notch goes on the right hand side with the air holes facing toward the door.
4)Important: push both baffles so they are tight against the side walls.
Front View
Note: When getting the chimney cleaned, push the baffles forward toward the front of the stove, this should leave sufficient access to the flue. If it is not enough space then remove the middleairtube(reversetheprocedure in step 1) above), and baffle and then replace everything when cleaning is completed.
16 | Regency Freestanding Woodstove |