INSTALLATION

ROOM AIR

IMPORTANT

For installation using room air for combustion, remove knockout from the pedestal, and/or from the bottom if using a heat shield.

Mobile home installations require the use of outside air.

On pedestal units there are two locations where

Note: Once the knockout is removed there

outside air may be adapted to the unit. If us-

are two tabs remaining. Bend both

ing the bottom of the pedestal, do not remove

tabs out for ease of installation when

knockout from the rear of the pedestal. Only

attaching outside air.

remove rear knockout if outside air will be

 

brought in from the rear.

 

On leg units outside air can only be brought in

 

from the bottom of the heat shield.

 

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Please read the section below carefully as clearances depend on whether the airmate or the rear heat deflector is installed on the stove.

Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall.

Clearances may only be reduced by means approved by the regulatory authority.

Residential Installation “C” Vent (Single Wall)

 

Unit

From Unit

From Corner

From Flue Center-Line

 

 

A

B

C

D

E

F

 

 

 

 

 

 

 

 

 

Medium F2400M with Airmate

16" (406 mm)

11" (279 mm)

6" (152 mm)

28" (710 mm)

17.5" (444 mm)

17.5" (444 mm)

 

with Rear Deflector

18" (457 mm)

12" (304 mm)

6.5" (165 mm)

30" (762 mm)

18.5" (469 mm)

19.5" (495 mm)

 

Medium S2400M Step Stove

16" (406 mm)

11" (279 mm)

6" (152 mm)

28" (710 mm)

17.5" (444 mm)

17.5" (444 mm)

 

 

 

 

 

 

 

 

Residential Close Clearance (To be installed with required pipe components)

When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level.

 

Unit

From Unit

From Corner

From Flue Center-Line

 

 

A

B

C

D

E

F

 

 

 

 

 

 

 

 

 

Medium F2400M with Airmate

15" (381 mm)

5.5" (139 mm)

4" (101 mm)

27" (685 mm)

12" (304 mm)

15.5" (393 mm)

 

with Rear Deflector

15" (381 mm)

6.5" (165 mm)

6" (152 mm)

27" (685 mm)

13" (330 mm)

17.5" (444 mm)

 

Medium S2400M Step Stove

15" (381 mm)

5.5" (139 mm)

4" (101 mm)

27" (685 mm)

12" (304 mm)

15.5" (393 mm)

 

 

 

 

 

 

 

 

Mobile Home Close Clearance (To be installed with required pipe components)

"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)

Unit

From Unit

 

From Corner

From Flue Center-Line

 

 

A

B

 

C

D

E

F

 

 

 

 

 

 

 

 

Medium F2400M

 

 

 

 

 

 

 

with Airmate

15" (381 mm)

5.5" (139 mm)

 

4" (101 mm)

27" (685 mm)

12" (304 mm)

15.5" (393 mm)

with Rear Deflector

15" (381 mm)

6.5" (165 mm)

 

6" (152 mm)

27" (685 mm)

13" (330 mm)

17.5" (444 mm)

Medium S2400M Step Stove

15" (381 mm)

5.5" (139 mm)

 

4" (101 mm)

27" (685 mm)

12" (304 mm)

15.5" (393 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Regency Freestanding Woodstove

Page 8
Image 8
Regency F2400M, S2400M Room AIR, Minimum Clearance to Combustible Materials, Residential Installation C Vent Single Wall