Regency S2400M, F2400M installation manual Mobile Home Installation

Models: S2400M F2400M

1 28
Download 28 pages 23.6 Kb
Page 15
Image 15
MOBILE HOME INSTALLATION

INSTALLATION

MOBILE HOME INSTALLATION

Once you have properly marked the position of your unit and the floor protection as outlined in the Residential Installation items #1 through #8, a supply of fresh air has to be supplied to your unit. Cut a minimum 4" (102mm) diameter hole through your floor protector and the floor directly under your pedestal base to the outside. Use 4" (102mm) duct pipe with a mesh grill to pipe fresh air into the pedestal area. Block off the hole in the back of the pedestal with the square plate and the two 1/2" screws provided.

Place your unit in position and secure it to the floor using two lag bolts 3/8" (10mm) x 3-1/2" (89mm) through the two holes inside the pedestal base. It is important to maintain the structural integrity of the Mobile Home floor, walls and roof when installing your unit.

For Mobile Home units installed in the U.S. the unit must be grounded using a #8 ground wire with approved termination and star washer.

CAUTION: At no time use unlabelled parts, or substitute parts made for another chimney system.

Install as per chimney manufacturer's installation instructions.

WARNING: Operate only with door fully closed - open feed door to feed fire only.

In addition to standard installation instructions the following requirements are mandatory for installation in a mobile home.

1)The stove must be permanently bolted to the floor of the Mobile Home using the floor screws provided.

2)The stove must have a permanent outside air source for combustion.

3)The stove must be electrically grounded to the steel chassis of the Mobile Home.

4)A listed double-wall connector chimney system, roof thimble, spark arrestor and roof flashing kit suitable for use in Mobile Homes must be used.

5)If the chimney exits the Mobile Home at a location other than through the roof, and exits at a point 7ft. (2130mm) or less above the ground level on which the Mobile Home is positioned a guard or method of enclosing the chimney shall be fitted at the point of exit for a height up to 7ft. (2130mm).

6)The chimney shall be attached directly to the room heater and shall extend at least 3 ft. (914mm) above the part of the roof through which it passes. The top of the chimney should project at least 2ft. (610mm) above the highest elevation of any part of the Mobile Home within 10 ft. (3048mm) of the chimney.

7)The chimney system shall comply with Local Requirements.

8)Any openings in a chimney guard where required must not permit the entrance of 3/4" (19mm) diameter rod.

9)CAUTION: THE STRUCTURALINTEGRITY OF THE MOBILE HOME ROOF, FLOOR, WALLS AND CEILING MUST BE MAIN- TAINED.

10)Check any other local building code as other local codes may apply.

11)WARNING: DO NOT INSTALLINASLEEP- ING ROOM OF A MOBILE HOME.

12)Use silicone to create an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure.

Regency Freestanding Woodstove

15

Page 15
Image 15
Regency S2400M, F2400M installation manual Mobile Home Installation