Regency F38-NG2, F38-LPG2 installation manual CONVERSION KIT# 731-968FROM NG TO LPG, Installation

Models: F38-NG2 F38-LPG2

1 23
Download 23 pages 29.8 Kb
Page 8
Image 8
CONVERSION KIT# 731-968 FROM NG TO LPG

INSTALLATION

CONVERSION KIT# 731-968 FROM NG TO LPG

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

LPG Conversion Kit Contains:

Qty.

Part #

Description

1

910-037

LPG Injector

 

 

(Pilot Orifice)

1

904-390

Burner Orifice #52

1

908-528

Red "LPG" label

1

908-255

Label "Converted to

 

 

LPG"

1904-529 5/32" Allen Key

1)Shut off the gas supply.

2)Open the front door and carefully remove the logs and lava rock.

3)Remove burner. See diagram below.

Note: Use a magnetic type screwdriver if possible.

Pilot assembly is now accessible

for steps 4) to 9).

4) Open pedestal door and remove the gold

chain from door which will allow door to

fall.

9)Insert a 5/32” or

4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.

Fig.3

10)Check that the screw is clean and if necessary remove dirt.

11)Flip the screw (Fig. 3).

12)Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.

Fig.2

Fig.4

WARNING!

Do not over tighten the screw. Recommended to grip the wrench by the short side.

13)Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o-ring visible (Fig. 5).

WARNING!

Also check that the pilot

and main burner injectors are appropriate for the gas type.

15)Pull off the pilot cap to expose the pilot orifice.

16)Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit.

17)Remove burner orifice with a 1/2" wrench while using a 9/16" wrench to hold onto the elbow behind the orifice, then discard the orifice.

5)

Remove lighting panel by removing the 6

 

Phillips head screws and put to the side.

6)

Remove hi-low extension knob.

7) Turn control knob to

 

 

 

the “OFF” position.

Red o-ring visible

Fig.5

LPG Configuration

Burner Orifice

18)

Reinstall new burner orifice LPG stamped

 

#52 and tighten.

19)

Reverse steps 3) to 2).

8) Remove the black protection cap by hand from the high- low knob (Fig.1).

Fig. 1

14) Re-assemble the black protection cap (Fig. 6).

Fig. 6

20)

Attach the label "This unit has been con-

 

verted to LPG" near or on top of the Serial

 

# decal.

21)

Replace yellow "NG" label with red "LPG"

 

label.

8

Regency F38-2 Freestanding Gas Stove

Page 8
Image 8
Regency F38-NG2, F38-LPG2 installation manual CONVERSION KIT# 731-968FROM NG TO LPG, Installation