INSTALLATION
FAN / BLOWER
Your fan should only be installed once the unit is in place in order to prevent any damage to the fan. To attach, follow the instructions provided with the fan. Make sure to install the rubber grommet to the fan housing before it is installed on the insert.
1)Remove the protective covering from the brass trim on the fan.
2)Align the fan support with the offset clip on the bottom of the ashlip.
Sensor
Switch
Thermo
3)Slide the supports into the clips. The tension holding the clips in place may be adjusted by increasing or decreasing the offset spacing of the clips.
4)Ensure that the power cord is not in contact with any hot stove surfaces.
5)Push the Regency logo plate into the two holes in the front bottom left corner of the fan.
Sensor
Switch
Thermo
Do not turn fan ON until your insert has reached operating temperature or at least 30 minutes after starting fire.
CAUTION: Label all wires prior to disconnection when servic- ing controls. Wiring errors can cause improper and dangerous operation.
WARNING:
Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into
aproperly grounded
Neutral |
|
|
|
|
|
|
Live | Green | Manual/ | Fan |
|
|
|
Ground | Auto |
|
|
| ||
120V AC |
| Switch | Switch |
|
|
|
60 Hz |
|
|
|
| ||
|
|
|
| White |
| |
Fan Thermodisc |
|
|
| Low |
| |
(normally open) | Black |
| Black | (Red) |
|
|
|
|
|
| |||
| Black |
| High |
|
| |
|
| (Black) |
|
|
| |
|
|
|
|
|
| |
|
|
| Fan |
| Fan | Ground |
|
|
|
|
|
|
Blower/Fan Wiring Diagram
10 | Regency Wood Insert & Hearth Heater |