Regency I3100L, H2100 installation manual Installation, Optional Flue Connector Kit

Models: H2100 I3100L

1 20
Download 20 pages 44.09 Kb
Page 7
Image 7
OPTIONAL FLUE

INSTALLATION

Position the grill on the inside bodyface side and fasten using the bolts, washers and nuts provided (2 per side) as shown in the diagrams.

Note: The grill has a front and rear, the holes on the front side have rounded edges and the rear holes have flat edges.

View from Rear of Insert

OPTIONAL FLUE

CONNECTOR KIT

The optional Flue Connector Kit (Part # 846-527) and the Straight Flue Adaptor (Part #846-504) shown here, may be used to produce a secure connection between your flue connector and the insert collar. Detailed installation instructions are included with the kit.

MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES

The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below.

 

Adjacent

Mantle**

Top

Side

Minimum

Minimum

Minimum

Unit

Side Wall

(to Top)

Facing

Facing

Hearth

Hearth

Hearth Side

 

(to Side)

 

(to Top)

(to Side)

Extension*

Thickness*

Extension

 

A

B

C

D

E

F

G

Large Flush

 

 

 

 

 

 

 

Insert (I3100L)

13"/330mm

19"/480mm

18"/455mm

6.5"/165mm

16"/406mm

1.5"/38mm

8"/205mm

 

 

 

 

 

 

 

 

Hearth Heater

 

 

 

 

 

 

 

(H2100M)

10"/255mm

25"/635 mm

14"/355mm

8.5"/216mm

18"/455mm

1.5"/38mm

6"/152mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side and Top facing is a maximum of 1.5" thick.

Floor protection must non-combustible, insula- tive material with an R value of 1.1 or greater.

*If the hearth extension is flush with the floor

(F)it must extend 19.5" in front of the body face (E).

Note: Hearth Extension Width (G) is meas- ured from edge of fuel door to side of hearth.

**A non-combustible mantel may be in- stalled at a lower height if the framing is made of metal studs covered with a non-combustible board.

Thermal floor protection is not required if the unit is raised 3.5" minimum (measured from the bottom of the stove). However, standard ember floor protection is required. It will need to be a non-combustible material that covers 16" (406 mm) in the US and 18" (450 mm) in Canada to the front of the unit and 8" (200 mm) to the sides.

If the unit is not raised, thermal floor protec- tion required is 18" (450 mm) in the US and Canada.

Clearance diagram for installations

Regency Wood Insert & Hearth Heater

7

Page 7
Image 7
Regency I3100L, H2100 Installation, Optional Flue Connector Kit, Masonry And Factory Built Fireplace Clearances