INSTALLATION
Position the grill on the inside bodyface side and fasten using the bolts, washers and nuts provided (2 per side) as shown in the diagrams.
Note: The grill has a front and rear, the holes on the front side have rounded edges and the rear holes have flat edges.
View from Rear of Insert
OPTIONAL FLUE
CONNECTOR KIT
The optional Flue Connector Kit (Part #
MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES
The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below.
| Adjacent | Mantle** | Top | Side | Minimum | Minimum | Minimum |
Unit | Side Wall | (to Top) | Facing | Facing | Hearth | Hearth | Hearth Side |
| (to Side) |
| (to Top) | (to Side) | Extension* | Thickness* | Extension |
| A | B | C | D | E | F | G |
Large Flush |
|
|
|
|
|
|
|
Insert (I3100L) | 13"/330mm | 19"/480mm | 18"/455mm | 6.5"/165mm | 16"/406mm | 1.5"/38mm | 8"/205mm |
|
|
|
|
|
|
|
|
Hearth Heater |
|
|
|
|
|
|
|
(H2100M) | 10"/255mm | 25"/635 mm | 14"/355mm | 8.5"/216mm | 18"/455mm | 1.5"/38mm | 6"/152mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Side and Top facing is a maximum of 1.5" thick.
Floor protection must
*If the hearth extension is flush with the floor
(F)it must extend 19.5" in front of the body face (E).
Note: Hearth Extension Width (G) is meas- ured from edge of fuel door to side of hearth.
**A
Thermal floor protection is not required if the unit is raised 3.5" minimum (measured from the bottom of the stove). However, standard ember floor protection is required. It will need to be a
If the unit is not raised, thermal floor protec- tion required is 18" (450 mm) in the US and Canada.
Clearance diagram for installations