Regency Installation, Faceplate And Trim, AH2100M and I3100L Insert, B All units

Models: H2100 I3100L

1 20
Download 20 pages 44.09 Kb
Page 9
Image 9
FACEPLATE AND TRIM

INSTALLATION

4)If the floor of your fireplace is below the level of the fireplace opening, adjust the insert's levelling bolts to accommodate the difference. When additional shimming is required, use non-combustible masonry or steel shims.

5)Measure approximately the alignment of the flue liner with the position of the smoke outlet hole on the insert to check for pos- sible offset. If an offset is required, use a proper stainless steel unit available with the chimney liner.

FACEPLATE AND TRIM

Prior to sliding your insert into its final position and attaching the connector or liner pipe, the faceplate side panel plates must be installed as follows:

A)H2100M and I3100L Insert

1)Slide the spring nuts (supplied) over the slots in the insert’s side convection panels (the spring nuts may need to be squeezed with a pair of pliers first, to help them stay in position).

2)Screw the side faceplate panels, (item A in the diagram) one to each side.

3)Using the top panel (item B in the diagram) as a gauge, check that the side panels are within approximately 1/4" of the overall width. If the difference is greater than this, use the supplied washers to attain the required width.

B) All units

The unit may now be slid into final position and attached to the connection system.

Once connection is made, the insulation strips should be installed between the insert faceplates and the fireplace face. The faceplate top may now be installed (with insulation strip behind) by aligning its brackets with the top flange on the side shields and the angle iron bar on the insert top. The faceplate trim may be installed to the edge of the faceplate at this time.

Note: It may be easier to install the insula- tion, faceplate top and faceplate trim with the unit pulled slightly away from the fireplace face. If this is done, be very careful not to disturb the con- nector when shifting the unit to its final position.

Now that your insert is installed, check once more that all the clearances from the unit to any combustible materials are correct as listed earlier.

Flush Inserts

Hearth Heater

6) Once the above items have been checked, slide your insert into position after first po- sitioning the flue liner and offset if required. (Re-install raincap at completion of installa- tion).

Diagram 1:

H2100M and I3100L

Faceplate Assembly

Regency Wood Insert & Hearth Heater

9

Page 9
Image 9
Regency installation manual Installation, Faceplate And Trim, AH2100M and I3100L Insert, B All units, Flush Inserts