MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES

INSTALLATION

MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES

The minimum required clearances to combustible materials when installed into a masonry or factory built fi replace are listed below.

 

Adjacent

Mantle**

Top

Side

Minimum

Minimum

Minimum

Unit

Side Wall

(to Top)

Facing

Facing

Hearth

Hearth

Hearth Side

 

(to Side)

 

(to Top)

(to Side)

Extension*

Thickness*

Extension

 

A

B

C

D

E

F

G

 

 

 

 

 

 

 

 

I1200S

15" (381mm)

20" (508mm)

14" (356mm)

7.375"(187mm) 16" (406mm)

1.5" (38mm)

8" (203mm)

Side and Top facing is a maximum of 1.5" thick. Floor protection must non-combustible, insulative material with an R value of 1.1 or greater.

* If the hearth extension is fl ush with the fl oor (F) it must extend 19.5" in front of the body face

(E).

Note: Hearth Extension Width (G) is meas- ured from edge of fuel door to side of hearth.

** A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.

Floor Protection

Please check to ensure that your floor protection and hearth will meet the standards for clearance to combustibles. Your hearth extension must be made from a non-combustible material.

Clearance diagram for installations

HOW TO DETERMINE IF ALTERNATE

FLOOR PROTECTION MATERIALS ARE ACCEPTABLE

The specifi ed floor protector should be 3/8" (18mm) thick material with a K - factor of 0.84.

The proposed alternative is 4" (100mm) brick with a C-factor of 1.25 over 1/8" (3mm) mineral board with a K-factor of 0.29.

Step (a):

Use formula above to convert specifi cation to R-value.

R = 1/k x T = 1/0.84 x .75 = 0.893.

Step (b):

Calculate R of proposed system. 4" brick of C = 1.25, therefore Rbrick = 1/C = 1/1.25 = 0.80

1/8" mineral board of k = 0.29, therefore Rmin.bd. = 1/0.29 x 0.125 = 0.431 Total R = Rbrick + Rmineral board = 0.8 + 0.431 = 1.231.

Step (c):

Compare proposed system R of 1.231 to specified R of 0.893. Since proposed system R is greater than required, the system is acceptable.

DEFINITIONS

Thermal Conductance:

C

=

Btu

 

=

W

 

 

(hr)(ft2 )(oF)

 

(m2))(K)

Thermal Conductivity:

 

 

k

= (Btu)(inch)

=

W

= Btu

(hr)(ft3)(oF)

(m)(K)

(hr)(ft)(oF)

Thermal Resistance:

 

 

R

= (ft2)(hr)(oF)

=

(m2)(K)

 

 

Btu

 

W

 

8