MAINTENANCE

MAINTENANCE

3)Only burn seasoned wood! Avoid burning wet or green wood. Seasoned wood has been dried at least one year.

4)A small hot fi re is preferable to a large smouldering one that can deposit creosote within the system.

5)Check the chimney at least twice a month during the burning season for creosote build-up.

6)Have chimney system and unit cleaned by competent chimney sweeps twice a year during the fi rst year of use and at least once a year thereafter or when needed.

DOOR LATCH

ADJUSTMENT

The door latch may require adjustment as the door gasket material compresses over time. Removal of the spacer washer, shown in the diagram below, will allow the latch to be moved closer to the door frame, causing a tighter seal. Remove and replace the nuts, washer as shown.

GLASS REMOVAL

Allowthestovetocoolbeforeremovingorreplac- ing glass. Remove the door from the insert and remove the glass retainer. Use caution when removing broken glass to prevent injury.

When placing the replacement glass in the door, make sure that the glass gasketing will properly seal your unit. Replace the retainer and tighten securely, but do not wrench down on the glass as this may cause breakage. Do not substitute materials. If your glass door does break, do not continue to use your unit until it has been replaced.

MAINTENANCE OF

GOLD-PLATED DOORS

The gold electroplated fi nish on the doors requires little maintenance, and need only be cleanedwithadampcloth.DONOTuseabrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty.

DOOR GASKET

If the door gasket requires replacement, 7/8" diameter material must be used. A proper high temperature gasket adhesive is required. A gasket repair kit, Part # 846-570 is available from your local Regency dealer.

GLASS CLEANING

Do not attempt to clean the glass when it is hot, allow the glass to cool before cleaning.

Do not use abrasive cleaners to clean the glass. Your local retailer can supply you with special glass cleaner if plain water and a soft cloth does not remove all deposits.

GLASS

REPLACEMENT

Your Regency Insert is supplied with 5 mm. Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact

-purchase your replacement from an authorized Regencydealeronly,andfollowourstep-by-step instructions.