Regency I2400M Installation, Step-By-Stepinstallation, Of The Faceplate And Trim

Models: I2400M

1 20
Download 20 pages 11.87 Kb
Page 10
Image 10
STEP-BY-STEP INSTALLATION

INSTALLATION

STEP-BY-STEP INSTALLATION

OF THE FACEPLATE AND TRIM

Prior to sliding your insert into its final position and attaching the connector or liner pipe, the faceplate side panel plates must be installed as follows:

1)Slide the spring nuts (supplied) over the slots in the insert’s side convection panels (the spring nuts may need to be squeezed with a pair of pliers first, to help them stay in position).

2)Screw the side faceplate panels, (item A in the diagram) one to each side.

3)Using the top panel (item B in the diagram) as a gauge, check that the side panels are within approximately 1/4" of the overall width. If the difference is greater than this, use the supplied washers to attain the required width.

4)The unit may now be slid into final position and attached to the connection system.

5)Once connection is made, the insulation strips should be installed between the insert face- plates and the fireplace face. The faceplate top may now be installed (with insulation strip behind) by aligning its brackets with the top flange on the side shields and the angle iron bar on the insert top. The faceplate trim may be installed to the edge

of the faceplate at this time.

Note: It may be easier to install the insula- tion, faceplate top and faceplate trim with the unit pulled slightly away from the fireplace face. If this is done, be very careful not to disturb the con- nector when shifting the unit to its final position.

Now that your insert is installed, check once more that all the clearances from the unit to any combustible materials are correct as listed earlier.

Faceplate Assembly

10

Regency I2400M

Page 10
Image 10
Regency I2400M installation manual Installation, Step-By-Stepinstallation, Of The Faceplate And Trim, Faceplate Assembly