Gas Fireplaces
Horizontal Venting with Two (2) 90° Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
Option | V | H+ H1 | Maximum total pipe: length, of | |
|
|
| all sections, must not exceed | |
A) | 1’ Min. | 2’ Max. | ||
37 feet. | ||||
|
|
| ||
B) | 2’ Min. | 5’ Max. | Total horizontal sections must | |
|
|
| not exceed 15 feet. | |
C) | 3’ Min. | 8’ Max. | ||
Minimum of 1 foot between | ||||
|
|
| ||
D) | 4’ Min. | 11’ Max. | 90° elbows is required. | |
E) | 5’ Min. | 14’ Max. |
| |
|
|
|
| |
F) | 6’ Min. | 15’ Max. |
|
Horizontal Venting with Two (2) 90° Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
Option | H | V | H + H1 | Maximum total pipe: length, of | |
|
|
|
| all sections, must not exceed | |
A) | 1’ Max. | 1’ Min. | 3’ Max. | ||
37 feet. | |||||
|
|
|
| ||
B) | 3’ Max. | 2’ Min. | 6’ Max. | Total horizontal sections must | |
|
|
|
| not exceed 12 feet. | |
C) | 5’ Max. | 3’ Min. | 9’ Max. | ||
Minimum of 1 foot between | |||||
D) | 8’ Max. | 5’ Min. | 12’ Max. | 90° elbows is required. | |
|
|
|
|
|
June 2007 Regency Product Specifications Book
Horizontal Venting with Three (3) 90° Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
Option | V+ V1 | H + H1 | Maximum total pipe: length, | |
|
|
| of all sections, must not | |
A) | 2’ Min. | 3’ Max. | ||
exceed 37 feet. | ||||
|
|
| ||
B) | 3’ Min. | 6’ Max. | Total horizontal sections | |
|
|
| must not exceed 12 feet. | |
C) | 4’ Min. | 9’ Max. | ||
Minimum of 1 foot between | ||||
|
|
| ||
D) | 5’ Min. | 12’ Max. | 90° elbows is required. |
Horizontal Venting with Three (3) 90° Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
Option | H | V | H + H1 + H2 | Maximum total pipe: length, of | |
|
|
|
| all sections, must not exceed | |
A) | 1’ Max. | 2’ Min. | 3’ Max. | ||
37 feet. | |||||
|
|
|
| Total horizontal sections must | |
B) | 3’ Max. | 3’ Min. | 6’ Max. | ||
not exceed 12 feet. | |||||
|
|
|
| Minimum of 1 foot between | |
C) | 5’ Max. | 4’ Min. | 9’ Max. | ||
90° elbows is required. | |||||
|
|
|
| ||
|
|
|
|
| |
F) | 7’ Max. | 5’ Min. | 12’ Max. |
| |
|
|
|
|
|
75