Vertical Venting with Two (2) 90° Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V+ V1

H

Maximum total pipe: length, of

 

 

 

all sections, must not exceed

A)

1’ Min.

4’ Max.

37 feet.

 

 

 

B)

2’ Min.

6’ Max.

Total horizontal sections must

 

 

 

not exceed 17 feet.

C)

3’ Min.

9’ Max.

Minimum of 1 foot between

 

 

 

D)

4’ Min.

12’ Max.

90° elbows is required.

E)

5’ Min.

15’ Max.

 

 

 

 

 

E)

6’ Min.

17’ Max.

 

Vertical Venting with Two (2) 90° Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

H + H1

V

Maximum total pipe: length, of

 

 

 

all sections, must not exceed

A)

2’ Max.

1’ Min.

37 feet.

 

 

 

B)

4’ Max.

2’ Min.

Total horizontal sections must

 

 

 

not exceed 8 feet.

C)

6’ Max.

3’ Min.

Minimum of 1 foot between

 

 

 

D)

8’ Max.

4’ Min.

90° elbows is required.

 

 

 

 

June 2007 Regency Product Specifications Book

P121-P131 Gas Fireplace

Vertical Venting with Three (3) 90° Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V+ V1

H + H1

Maximum total pipe: length, of

 

 

 

all sections, must not exceed

A)

2’ Min.

3’ Max.

37 feet.

 

 

 

B)

3’ Min.

6’ Max.

Total horizontal sections must not

 

 

 

exceed 12 feet.

C)

4’ Min.

9’ Max.

Minimum of 1 foot between 90°

 

 

 

D)

5’ Min.

12’ Max.

elbows is required.

Vertical Venting with Three (3) 90° Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

V+ V1

H

H + H1

Maximum total pipe: length, of

 

 

 

 

all sections, must not exceed

A)

2’ Min.

1’ Max.

2’ Max.

37 feet.

 

 

 

 

Total horizontal sections must

B)

3’ Min.

4’ Max.

5’ Max.

not exceed 12 feet.

 

 

 

 

Minimum of 1 foot between 90°

C)

4’ Min.

6’ Max.

8’ Max.

elbows is required.

 

 

 

 

D)

5’ Min.

8’ Max.

12’ Max.

 

 

 

 

 

 

73

Gas Fireplaces

Page 5
Image 5