Regency Wraps F38-NG2 Maintenance Instructions, Log Replacement, Door And Glass Gasket

Models: F38-NG2 F38-LPG2

1 24
Download 24 pages 29.98 Kb
Page 17
Image 17
MAINTENANCE

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1)Always shut the valve off before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean brush as the logs are fragile and easily damaged.

2)Clean glass (never when unit is hot), appli- ance, louvres, and door with a damp cloth. Never use an abrasive cleaner. The gold louvres (and optional gold door) may be scratched if abrasives are used to clean them.

The heater is fi nished in a heat resistant paint and should only be refi nished with heat resistant paint (not with wall paint). Regency uses StoveBright Paint - Metallic Black #6309.

3)Make a periodic check of burner for proper position and condition. Visually check the flame of the burnerperiodically,makingsure the fl ames are steady; not lifting or fl oating. If there is a problem, call an authorized service person.

4)The appliance and fl ueing system must be inspected before use, and at least annu- ally, by an authorized fi eld service person, to ensure that the fl ow of combustion and ventilation air is not obstructed.

During the annual service call, the burners should be removed from the burner tray and cleaned. Replace the embers - do not block the pilot or burner ports.

5)Keep the area near the appliance clear and free from combustible materials, gasoline and other fl ammable

vapours and liquids.

WARNING:CHILDRENANDADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CARE- FULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV- ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE AP- PLIANCE.

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL AN AUTHORIZED SERVICE TECHNI- CIAN TO INSPECT THEAPPLIANCE AND TO REPLACE ANY PART OF CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UN- DER WATER.

6)Verify proper operation after servicing.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

Note: Improper positioning of logs may cre- ate carbon build-up and will alter the unit’s performance which is not covered under warranty.

DOOR AND

GLASS GASKET

If the door gasket requires replacement use 7/8" diameter oval door gasket (Part # 650-920). The glass requires 5/8" fl at glass gasket. See your Regency dealer.

GOLD-PLATED DOORS

The 24 carat gold plated fi nish on the door requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and will void the warranty. Clean any fi ngerprints off before turning the unit on.

GLASS

REPLACEMENT

Your Regency heater is supplied with high temperature, 5mm Neoceram silica coated ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass, purchase your re- placement from an authorized Regency dealer only, and follow the step-by-step instructions for replacement.

Removing Glass:

Note: Wearing gloves will protect your

hands while handling glass.

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Pull out the door gasket.

3)Remove the 24 nuts holding the glass retainers in place. Do not remove the nuts underneath the retainers.

4)Remove the door catch plate.

5)Removeglassretainersonsidesfirst(3each side) then remove two center retainers.

Note: Center glass retainers are glued to center glass.

6)Remove glass from aluminium extrusions. When removing center glass, leave white insulation in place.

Safety Screen: Only required in Australia

Regency F38-2 Freestanding Gas Heater

17

Page 17
Image 17
Regency Wraps F38-NG2, F38-LPG2 Maintenance Instructions, Log Replacement, Door And Glass Gasket, Gold-Plateddoors