INSTALLATION

GENERAL

INFORMATION

This installation must conform with local codes or, in the absence of local codes, with AS5601- 2004 (Australia) NZS 5261 (New Zealand).

THIS APPLIANCE SHOULD

BE INSTALLED, REPAIRED,

INSPECTED BEFORE USE

AND AT LEAST ANNUALLY

BYAN AUTHORISED SERV-

ICE PERSON. MORE FRE- QUENT CLEANING MAY BE REQUIRED, DUE TO EXCESSIVE LINT FROM CAR- PETING, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENT, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERA-

TURES, THE APPLIANCE

SHOULD BE LOCATED OUT

OF TRAFFIC AND AWAY

FROM FURNITURE AND

DRAPERIES.

THISAPPLIANCE CAN ONLY

BEFLUEDINACCORDANCE

WITH AS5601-2004 OR LO-

CAL CODES.

FAILURE TO INSTALL THIS

APPLIANCE CORRECTLY

MAY CAUSE A SERIOUS

HOUSE FIRE.

Provide adequate clearances for servicing, properoperationandaroundtheairopeningsinto the combustion chamber.Adequate combustion and ventilation air must also be provided.

The appliance must be installed on a fl at, solid, continuous surface (i.e. wood, metal, concrete). This may be the fl oor, or it can be raised up on a platform to enhance its visual impact.

The Regency Freestanding Gas Heater can be installed in a wide variety of ways and will fi t nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a corner.

We recommend that you plan your installation on paper using exact measurements for clearances and fl oor protection before actually installing this appliance. If an existing chimney is not utilised, position the appliance to allow free passage of factory-built listed chimney through the ceiling and roof.

IMPORTANT

The F38-2 Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual first.Consultthe"authorityhavingjurisdiction"to determine the need for a permit prior to starting the installation.

BEFORE YOU START

INSTALLATION AND REPAIR SHOULD BE DONE BY AN AU- THORISED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY AN AU- THORISED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLI- ANCE BE KEPT CLEAN.

DUETOHIGHTEMPERATURES,THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY MAY CAUSE A SERIOUS HOUSE FIRE AND WILL VOID YOUR WAR- RANTY.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE.

GENERAL SAFETY

INFORMATION

1)The appliance shall be installed in accord- ance with the manufacturer's installation instructions, local gas fi tting regulations, municipal building codes, water supply regulations, electrical wiring regulations, with AS5601-2004 (AGA gas installation code) NZS 5261 (New Zealand)

2)Installation and repair should be done ONLY by an authorised person.

3)See general construction and assembly instructions. The appliance should be in- spected before use and at least annually by an authorised service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean and free from excessive lint from carpeting.

4)This appliance must be connected to a fl ue and terminate to the outside of the building envelope. Never fl ue to another room.

5)Inspect the fl ueing system annually for blockage and any signs of deterioration.

6)Any safety glass removed for servicing must be replaced prior to operating the ap- pliance.

7)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.

8)Wear gloves and safety glasses for protec- tion while doing required maintenance.

9)Under no circumstances should this ap- pliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

10)Installation and any repairs to this appliance should be done by an authorised service person.Anauthorisedservicepersonshould be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

11)Do not strike the glass door.

12)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

13)The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).

Regency F38-2 Freestanding Gas Heater

5

Page 5
Image 5
Regency Wraps F38-NG2, F38-LPG2 Installation, General Information, Before YOU Start, General Safety Information

F38-NG2, F38-LPG2 specifications

Regency Wraps is known for its innovative approach to creating stylish and functional clothing storage solutions. Among their notable offerings are the F38-NG2 and F38-LPG2 garment bags. These bags blend practicality and aesthetics, catering to the needs of individuals looking to store and transport their garments with care and style.

The F38-NG2 is designed with a focus on durability and protection. Made from high-quality nylon fabric, it provides excellent resistance to wear and tear while also being lightweight for easy handling. One of the key features of this garment bag is its spacious interior, allowing users to store multiple garments without worrying about creasing or damage. The innovative design includes breathable ventilation that helps prevent odors and keeps clothes fresh during travel or storage. Additionally, the translucent window enables quick visibility of the contents, eliminating the hassle of searching through a packed bag.

On the other hand, the F38-LPG2 caters to a slightly different demographic with its luxurious polyester fabric. This elegant material not only enhances the bag’s aesthetic appeal but also adds a layer of protection against dust, dirt, and moisture. The F38-LPG2 is particularly well-suited for formal attire, such as evening gowns and suits. Its padded interior offers extra cushioning for delicate fabrics, ensuring that garments remain in pristine condition. Like its counterpart, this bag features a convenient clear window, allowing users to identify garments at a glance.

Both the F38-NG2 and F38-LPG2 incorporate advanced technologies, such as anti-static linings. These linings help reduce static cling, providing an extra level of care for garments made from synthetic materials. Additionally, both bags come with sturdy zippers and reinforced handles for enhanced durability, ensuring that they can withstand the rigors of frequent use.

In conclusion, the Regency Wraps F38-NG2 and F38-LPG2 garment bags are ideal choices for individuals seeking quality and functionality in their clothing storage solutions. With their thoughtful designs, high-quality materials, and protective features, these bags are perfect for traveling, seasonal storage, or simply keeping your wardrobe organized. Whether you prefer the rugged advantage of the F38-NG2 or the sophisticated elegance of the F38-LPG2, both options reflect Regency Wraps' commitment to quality and innovation in garment care.