INSTALLATION
Flueing Requirements
A100mmdiameterflueisrequired. Forcosmetic or aesthetic purposes 6" outer fl ue can be used as long as an approved inner fl ue is installed. Fasten but do not penetrate the inner sleeve of the fl ue when tightening the screw.
The minimum fl ue required is 3.3m from fl oor level.
Follow all fl ueing manufacturer’s requirements and local building codes or
GAS CONNECTION
The gas line should be rigid pipe. Copper may also be used if approved by
The gas connection at the valve is 1/2 male. For minimum and maximum supply pressure see the System Data Table.
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas supply piping system by closing its individual manual
Themanifoldpressureiscontrolledbyaregulator built into the gas control, and should be checked at the pressure test point.
Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.
1)Make sure the valve is in the "OFF" posi- tion.
2)Loosen the "IN" (# 7) and/or "OUT" (# 6) pressure tap(s), turning counterclockwise with a 1/8" wide fl at screwdriver.
3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.
4)Light the pilot and turn the valve to "ON" position.
5)The pressure check should be carried out with the unit burning and the setting should be within the limits specifi ed on the safety label.
6)When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver. Screw should be snug, but do not over tighten.
S.I.T. Valve Description
1)Gas on/off knob
2)Manual high/low adjustment
3)Pilot Adjustment
4)Thermocouple Connection
5)Main Operator
6)Outlet Pressure Tap
7)Inlet Pressure Tap
8)Pilot Outlet
9)Main Gas Outlet
10)Flange Securing Screw Holes
11)Alternative TC Connection Point
12)Thermoelectric Unit
13)Additional Valve Mounting Hole
System Data
Burner Inlet Orifi ce Sizes: |
| |
| NG | LPG |
Burner | #33 | #52 |
|
|
|
Max. Input |
|
|
NG | 38 mj |
|
LPG | 31 mj |
|
|
|
|
Min. Input |
|
|
NG | 24.1 mj |
|
LPG | 24.5 mj |
|
|
|
|
Supply Pressure |
|
|
NG | 1.74 kPa |
|
LPG | 2.99 kPa |
|
|
|
|
Manifold Pressure |
|
|
NG | 0.87 kPa |
|
LPG | 2.65 kPa |
|
Electrical: 240 V. 50Hz.
Circulation: High/Off/LO speed fan, 150/89 CFM.
Log Set: Ceramic fi ber, 7 per set.
Aeration Setting
NG Full Open
LPG 6.4 mm
Flue Restrictor Setting
NG Full Open
LPG Full Open
Regency | 7 |