Operation

90˚

5.Place the muzzle of tool perpendicular to work surface without tilting the tool. Push tool against work surface until sliding action of barrel stops.

6.Squeeze trigger to set power fastener. Be sure to keep pressure on tool during this operation.

9

7.After fastening is made, slide barrel forward rapidly. This motion ejects the spent powder load and resets the piston for the next fastening. Make sure spent load has ejected from tool.

30

WATER

8.Should the tool fail to fire, hold the muzzle firmly against the work surface for 30 seconds. Release the trigger and remove pressure on the tool while holding the muzzle against the work surface. Again press the tool firmly against the work surface and pull the trigger. If the tool still fails to fire, hold the tool firmly against the work surface for another 30 seconds before unloading and carefully dis- carding the misfired powder load into water or oil.

101274

15

Page 15
Image 15
Remington 490, 489 operating instructions 90˚