42
Note: For the command line syntax, refer to the online help.
(a) Specifying the measurement start/end conditions
Set the performance measurement conditions in the [Action] page after conditions have been
set in the [Event Condition] dialog box that is opened by double-clicking Ch1 to Ch6 and Ch8
to Ch12 on the [Event Condition] sheet of the [Eventpoint] window.
Notes: 1. When no measurement start/end conditions are specified, measurement is started by
executing a program and ended when an event condition is satisfied.
2. When only the measurement start or end condition is specified, performance cannot be
measured. Be sure to specify both of the measurement start and end conditions.
3. When the measurement start/end conditions are specified, step operation cannot be
performed. In addition, when execution is restarted from the address where step
operation has been stopped by the break conditions of BREAKPOINT or Event
Condition, step functions are used and operation is disabled. Restart execution after
the settings of the break conditions of BREAKPOINT or Event Condition have been
canceled.
4. It is not possible to specify the break conditions and the measurement start/end
conditions at the same time with one channel. If the measurement start/end conditions
are specified, the settings of the break conditions will be disabled.