Table 2.11 Conditions Specified in the [Action] Page
Item Description
PA1 pa1_start_point Specifies the conditions of Event Condition that has been set as
the measurement start condition of performance channel 1.
pa1_end_point Specifies the conditions of Event Condition that has been set as
the measurement end condition of performance channel 1.
PA2 pa2_start_point Specifies the conditions of Event Condition that has been set as
the measurement start condition of performance channel 2.
pa2_end_point Specifies the conditions of Event Condition that has been set as
the measurement end condition of performance channel 2.
PA3 pa3_start_point Specifies the conditions of Event Condition that has been set as
the measurement start condition of performance channel 3.
pa3_end_point Specifies the conditions of Event Condition that has been set as
the measurement end condition of performance channel 3.
PA4 pa4_start_point Specifies the conditions of Event Condition that has been set as
the measurement start condition of performance channel 4.
pa4_end_point Specifies the conditions of Event Condition that has been set as
the measurement end condition of performance channel 4.