The following settings for the white balance can be set in the E2 menu.

10 WB Adjustable Range

Fixed, Auto Adjustment

Adjusting the White Balance Manually

You can measure the white balance at a selected location.

 

 

Auto White Balance, Multi

11 WB When Using Flash

Auto White Balance, Flash,

 

 

Unchanged

 

 

 

12

AWB in Tungsten Light

Strong Correction, Subtle

Correction

 

 

 

 

 

13

Color Temperature Steps

Kelvin, Mired

Manual White Balance

Adjust

 

 

WB±

 

OK

Cancel

Check

3

2Under the light you wish to measure the white balance of, select a white area as the subject, and press 0fully.

The captured image is displayed.

3Use ABCD to specify the measuring area.

CancelOK

4Press E.

The White Balance setting screen reappears.

[The operation could not be completed correctly] appears when measuring is unsuccessful. Press Eto remeasure the white balance and return to Step 3.

tMemo

You can copy the white balance settings of a captured image and save them as manual white balance settings in [Save as Manual WB] of the playback mode palette. (p.64)

Shooting