26/32
FV-L200B1
User’s Guide Rev. 1.01
Command No.
Command Descriptions
12H:
MOD3[7O0]
[Camera function mode setting 3] Initial data: 0
This sets the following camera function modes.
D[7O0]
D7 D6 D5 D4 D3 D2 D1 D0
D7~D6:
Video Out 00: 10bit 01: 8bit
10: 12bit
11: No function (Prohibited setting. Do not set these values)
D5: Trigger-in connector selection 0: Camera Link (CC1)
1: /IO connector (No.2 Pin)
D4~D3:
Exposure Start Mode 00: Normal 01: Reserved trigger
10 ~11: H reset
D2~D1:
No Function Set always “000”
D0 Look-up table (Gamma) 00: OFF 01: ON
14H:
UART[7O0]
[Communication mode] Initial Data: 01H
This sets the communication modes.
D[7O0]
D7 D6 D5 D4 D3 D2 D1 D0
D7~D2: No Function Set always “000000”
D1~D0: Communication Mode 00: 38,400 bps 01: 9,600 bps
10: 57,600 bps 11: 115,200 bps
1CH:
AGCMAX[7..0]
[AGC maximum limit] Initial data: 255, data range: 0 to 255
Sets the maximum limit for the AGC.
1DH:
ALCTRGT [7..0]
[Target Brightness for ALC] Initial data: 128, data range: 0 to 255
Sets the target brightness for the ALC function (Auto Luminance Control).
1EH:
ALCMODE[7..0]
[ALC mode] Initial data: 0
This sets the ALC modes.
D[7O0]
D7 D6 D5 D4 D3 D2 D1 D0
D7: Long exposure 0: OFF 1: ON
D6 to D2
No Function Set always “00000”
D1 AGC (Auto Gain Control) 0: OFF 1: ON
D0 AE (Auto Exposure) 0: OFF 1: ON
When using AE combined with the long exposure, exposure time is controlled regardless of the frame rate.
Therefore, the frame rate varies depending on the exposure time.