Command No. | Command Descriptions | |
20H: | [Exposure time (H) of the electronic shutter] Initial Data: SVR[150] = 0, Data Range: 0 to 4095 | |
SVR[70] | Sets the preset shutter speed (or CCD exposure time) for electronic shutter. | |
21H: |
|
|
SVR[158] | The preset shutter speed is defined by the following formula. | |
| Exposure time (shutter speed) = SVR[150] x (1H | cycle time) + SHR[150] x (1CLK cycle time) |
| Notes: |
|
| 1. The camera works with the shutter off position (maximum frame exposure time) when both SVR and SHR | |
| are set at “0”. |
|
| 2. The camera works with the minimum shutter speed when this value is set to 0 and the value of SHR is set | |
| between 1 and 306. |
|
| 3. The value is replaced with 4095 automatically when the value set greater than 4095. | |
|
| |
22H: | [Exposure time (CLK) of the electronic shutter] Initial Data: SHR[150] = 0, Data Range: 0 to 1919 | |
SHR[70] | Sets the preset shutter speed (or CCD exposure time) for electronic shutter. | |
23H: |
|
|
SHR[158] | The previous section, the preset shutter speed is defined by the following formula: | |
| Preset shutter speed = SVR[150] x (1H cycle ti | me) + SHR[150] x (1CLK cycle time) |
| Note 1: The camera works with the shutter off position (maximum frame exposure time) when both SVR and SHR | |
| are set at “0”. |
|
| Note 2: The camera works with the minimum shutter speed when SVR is set to 0 and this value is set between 1 | |
| and 306. |
|
| Note 3: The value replaces by 1919 automatically when the value set greater than 1919 | |
|
| |
24H: | [Start line of the variable partial scanning] Initial Data: PSR[150] = 0, Data Range: 0 to 1235 | |
PSR[7..0] | This sets the start line number of the variable partial scanning area. | |
25H: |
|
|
PSR[158] | Actual start line of the partial scanning = this value + 1 | |
| Note 1: The camera works with full scanning mode when the value of (PSR[ ] + PWR[ ]) is greater than 494. | |
| Note 2: The value replaces by 1235 automatically when the value set greater than 1235 | |
|
| |
26H: | [Effective line numbers in the variable partial scanning] Initial Data: PWR[150] = 494, Data Range: 0 to 1236 | |
PWR[70] | This sets the number of the total effective lines (image height) in the variable partial scanning mode. | |
27H: |
|
|
PWR[158] | Notes: |
|
| 1. The value replaces by 1236 automatically when the value set greater than 1236. | |
| 2. The camera works with full scanning mode when the value of (PSR[ ] + PWR[ ]) is greater than 2058. | |
|
|
|