2Camera Output Timing Charts

2.1

Normal Mode

 

 

(Setting

10H: 1XX0XXXX)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal Full Scanning

 

Partial Full Scanning

 

1/2 Partial Scanning

1/4 Partial Scanning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

Normal

x1/2

 

x1/4

Normal

 

x1/2

x1/4

 

Normal

x1/2

x1/4

Normal

x1/2

x1/4

(MHz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rate

15.3

7.6

 

3.8

 

15.4

 

7.7

3.9

 

30.6

15.3

7.7

61.3

30.6

15.3

(Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock Speed: 36.8181

MHz (Normal), 18.40905 MHzx1/2, 9.204525 MHzx1/4

 

 

2.1.1Horizontal Timing

1 CLK = 108.6422 ns at 3.8fps

1 CLK = 54.3211 ns at 7.6fps

1 CLK = 27.1605 ns at 15.3fps

LVAL

 

1920 CLK

 

 

One horizontal (1H)

 

 

 

 

DVAL

300 CLK1620 CLK300 CLK

FVAL

207 CLK

93

CLK

Video out

 

300 CLK

 

 

 

1620 CLK

 

 

 

300 CLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal blanking

Video output

 

 

FVL200B1

5/32

User’s Guide Rev. 1.01

 

Page 5
Image 5
Ricoh FV-L200B1 manual Normal Mode Setting 10H, Horizontal Timing