Model KT-190 and KT-200 Pipe Thawing Units

Standard Equipment

Qty. Item

1 ........Thawing Unit, Model KT-190 or KT-200. 115

volts, 15 Amps.

2 ........Cables, 25 feet in length, with a vinyl coated

spring clamp on one end and a mounting loop on the other.

Accessories

Extension Cable, 25 feet, # 1/0 AWG c/w nut & bolt. Catalog No. 62772

Series Cable, 3 feet, # 1/0 AWG Catalog No. 62812

Figure 1 – KT-200 Pipe Thawing Tool

Problem Diagnostics

Main Service Lines

If there is no running water anywhere in the house, the main service from the curb valve to the house is frozen. The service can be thawed by placing one clamp on a tap water line in the basement and the other on the curb key attached to the curb valve. Make sure there is contact be- tween the curb key and valve. Extension Cables are required if runs exceed 50 feet. Additional thawing units may be required to reduce thawing time. Refer to Special Application Procedure for Series Set-Up.

Tap Water Lines

Locate the frozen line by opening faucets and checking for water flow. The frozen section will normally be in an out- side wall or in a crawl space with poor insulation. If one faucet does not have running water and the next faucet does, frozen section is between faucets. Place clamps on either hot or cold water lines, not on faucets.

Refer to Thawing Tap Water Lines for procedure.

Cables and Clamps

25 feet in length with vinyl coated clamp.

KT-190KT-200

Size

#2 AWG

#1/0 AWG

Weight

19 lbs/Pair

23 lbs/Pair

 

(8.6 kgs)

(10.5 kgs)

 

Pipe Thawer

Curb Shut

 

Off Rod

 

 

Earth

Street Valve

Frozen Section

 

Figure 2 – Thawing Main Service Lines

4

Ridge Tool Company

Page 6
Image 6
RIDGID kt-190 manual Problem Diagnostics