RIDGID OL90150 manual Troubleshooting, Trouble Probable Cause Remedy

Models: OL90150

1 28
Download 28 pages 36.89 Kb
Page 20
Image 20

Troubleshooting

!WARNING:

For your own safety do not try and run the air compressor while troubleshooting.

TROUBLE

PROBABLE CAUSE

REMEDY

 

 

 

 

 

 

Compressor will not

1. Unit is plugged into

1. Remove extension cord

run

extension cord

 

 

2. No electrical power

2. Verify unit is plugged in.

 

 

Check fuse/breaker or

 

 

motor overload

 

3. Blown fuse

3. Replace blown fuse

 

4. Breaker open

4. Reset, determining why

 

 

problem happened

 

5. Thermal overload open

5. Motor will restart when cool

 

6. Pressure switch bad

6. Replace

 

 

 

Motor hums but can-

1. Low voltage

1. Check with voltmeter

not run or runs slow-

2. Unit is plugged into

2. Remove extension cord

ly

extension cord

 

 

3. Shorted or open motor

3. Replace motor

 

winding

 

 

4. Defective check valve or

4. Replace or repair

 

unloader

 

 

 

 

Fuses blow/circuit

1. Incorrect size fuse, circuit

1. Check for proper fuse, use

breaker trips repeat-

overloaded

time-delay fuse.

edly

 

Disconnect other electrical

 

 

appliances from circuit or

 

 

operate compressor on its

 

 

own branch circuit

 

2. Unit is plugged into

2. Remove extension cord

 

extension cord

 

 

3. Defective check valve or

3. Replace or repair

 

unloader

 

 

 

 

20

Page 20
Image 20
RIDGID OL90150 manual Troubleshooting, Trouble Probable Cause Remedy