adjustments
WARNING:
Before performing any adjustment, make sure the tool is unplugged from the power supply and the switch is in the OFF ( O ) position. Fail- ure to heed this warning could result in serious personal injury.
To avoid unnecessary
SMALL blade
WRENCH
LARGE
blade WRENCH
Fig. 42
TO replace the blade
See Figures 42 - 44.
NOTE: Arbor shaft has
Unplug the saw. |
Lower the saw blade and remove the throat plate. |
Raise the saw blade to full height then remove the blade |
guard and |
Make sure the bevel locking lever is locked. |
Insert the open end of the small blade wrench onto the |
flats on the arbor shaft. |
Insert the closed end of the large wrench over the hex |
nut. Holding both wrenches firmly, pull the outside wrench |
(right side) forward while pushing the inside (left side) to |
the back of the saw. |
Unlock the release locking lever and remove the blade. |
inner Blade
washer
spacer
Blade | OUTER Blade |
| washer |
Blade
nut
release lever
To install a standard blade:
Place the new blade on the arbor shaft (blade teeth must point down toward the front of the saw to work properly).
Place the blade washer and the blade nut over the arbor shaft. Be sure the dome side of the blade washer faces out from the blade and that all items are snug against the arbor housing. Make sure the blade nut is securely tightened. Do not overtighten.
Lock the release lever.
Rotate the blade by hand to make sure it turns freely.
Lower the saw blade and reinstall the throat plate.
NOTE: To replace the blade with an accessory blade, fol- low the instructions provided with the accessory.
arbor |
|
shaft | Fig. 43 |
THROAT
PLATEspreader/
RIVING KNIFE
BLADE
Fig. 44
33