Connecting the Appliance

1.

Attach flue adapter to the flue manifold with Flue Adapter

Pipe stopper S

Plastic tie

Flue Manifold

 

 

pipe stopper S.

 

 

2.

Attach the air inlet hose to the flue manifold.

 

 

Secure with plastic tie. The unused inlet is plugged with the rubber cap supplied on the

manifold.

Inlet elbow

 

 

Inlet hose

3.Connect the vent sliding tube with pipe stopper S and E. The sliding tube should not be extended beyond the red line. The red line should not be visible after sliding the tube into the vent outlet.

Flue Manifold

Screw

Sliding Tube

 

PIPE STOPPER S

PIPE STOPPER A

PIPE STOPPER E

4. Slide the insulation sleeve up to the flue manifold and slip the securing clip over the sleeve as shown.

5. Attach the appliance to the wall brackets, using 2 screws at each bracket.

SCREW M5

6.Attach the back spacer with 3 screws to the top of the appliance.

7.If necessary, the appliance can be leveled using the adjustable legs under the front right and left legs.

26

Rinnai Corporation ES38 Manual

Page 26
Image 26
Rinnai ES38 installation manual Connecting the Appliance