Rinnai EX17C installation manual Safety Features, Appliance Specifications, EX22C

Models: EX22C EX17C

1 84
Download 84 pages 56.01 Kb
Page 4
Image 4
Safety Features

Safety Features

Overheat: The appliance will automatically shut down when the appliance exceeds a predetermined temperature.

Flame Failure: The appliance will automatically shut down if the burner flame is extinguished.

Power Failure: The appliance will shut off the gas if it loses electrical power.

Power Surge Fuse: A glass fuse on the PC board protects against overcurrent. If the fuse blows then all indicator lamps will be off.

Spark Detector: The appliance automatically shuts down if there is an abnormal spark at ignition.

Fusible Link: In case the overheat feature does not prevent an overheat then the fusible link could break, shutting off the appliance.

Specifications

Appliance Specifications

 

EX17C

 

EX22C

Application

For manufactured home (USA only) or mobile home or residential installation convertible

 

for use with natural gas and liquefied petroleum gases (propane / LPG) when provision is

 

made for the simple conversion from one gas to the other.

 

 

For commercial setting.

 

 

 

 

For installation at altitudes up to 10,200 feet (3109 m).

 

General Description

Forced combustion, forced convection, flued gas furnace

 

 

 

 

 

 

Operation

Push button electronic

 

 

 

 

 

 

 

 

Gas Connection

1/2 in male NPT

 

 

 

 

 

 

 

 

Gas Control

Electronic

 

 

 

 

 

 

 

Burners

Stainless steel Bunsen burner

 

 

 

 

 

Temperature Control

Electronic thermostat, (Low, 60-80ºF in 2ºF increments, High)

 

 

 

 

 

 

Ignition System

Electronic spark ignition

 

 

 

 

 

Flue System

The flue must be terminated to atmosphere with only flue components listed with the

 

appliance’s certification. Warranty will be voided if non listed components are installed.

 

 

 

 

Humidifier Tray

Capacity - 2.1 pints (1000 cc)

 

 

 

 

 

Electrical Connection

AC 120V, 60 Hz, 46 watts

AC 120V, 60 Hz, 56 watts

 

 

 

 

 

Standby Power

0.5 watt

 

 

 

 

 

 

 

 

Weight

57 lbs (26 kg)

 

 

 

 

 

 

 

 

Noise Level

33-38 dB

 

33-42 dB

 

 

 

 

 

 

AFUE Rating

Natural Gas: 81%

Propane: 82%

Natural Gas: 80%

Propane: 82%

 

 

 

 

 

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.

The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.

4

Rinnai Corporation EX17C / EX22C Manual

Page 4
Image 4
Rinnai EX17C installation manual Safety Features, Appliance Specifications, EX22C