Safety Features
•Overheat: The appliance will automatically shut down when the appliance exceeds a predetermined temperature.
•Flame Failure: The appliance will automatically shut down if the burner flame is extinguished.
•Power Failure: The appliance will shut off the gas if it loses electrical power.
•Power Surge Fuse: A glass fuse on the PC board protects against overcurrent. If the fuse blows then all indicator lamps will be off.
•Spark Detector: The appliance automatically shuts down if there is an abnormal spark at ignition.
•Fusible Link: In case the overheat feature does not prevent an overheat then the fusible link could break, shutting off the appliance.
Specifications
Appliance Specifications
| EX17C |
| EX22C | |
Application | For manufactured home (USA only) or mobile home or residential installation convertible | |||
| for use with natural gas and liquefied petroleum gases (propane / LPG) when provision is | |||
| made for the simple conversion from one gas to the other. |
| ||
| For commercial setting. |
|
|
|
| For installation at altitudes up to 10,200 feet (3109 m). |
| ||
General Description | Forced combustion, forced convection, flued gas furnace |
| ||
|
|
|
|
|
Operation | Push button electronic |
|
|
|
|
|
|
|
|
Gas Connection | 1/2 in male NPT |
|
|
|
|
|
|
|
|
Gas Control | Electronic |
|
|
|
|
|
|
| |
Burners | Stainless steel Bunsen burner |
|
| |
|
|
| ||
Temperature Control | Electronic thermostat, (Low, |
| ||
|
|
|
|
|
Ignition System | Electronic spark ignition |
|
|
|
|
| |||
Flue System | The flue must be terminated to atmosphere with only flue components listed with the | |||
| appliance’s certification. Warranty will be voided if non listed components are installed. | |||
|
|
|
| |
Humidifier Tray | Capacity - 2.1 pints (1000 cc) |
|
| |
|
|
| ||
Electrical Connection | AC 120V, 60 Hz, 46 watts | AC 120V, 60 Hz, 56 watts | ||
|
|
|
|
|
Standby Power | 0.5 watt |
|
|
|
|
|
|
|
|
Weight | 57 lbs (26 kg) |
|
|
|
|
|
|
|
|
Noise Level |
|
| ||
|
|
|
|
|
AFUE Rating | Natural Gas: 81% | Propane: 82% | Natural Gas: 80% | Propane: 82% |
|
|
|
|
|
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.