Rinnai EX22C Flue Terminal Clearances, Description, Canadian Installations, US Installations

Models: EX22C EX17C

1 84
Download 84 pages 56.01 Kb
Page 19
Image 19
Description

Flue Terminal Clearances

Ref

Description

Canadian Installations

US Installations

 

 

 

 

 

Clearance above grade, veranda,

 

 

A

porch, deck, or balcony. (Take into

12 inches (30 cm)

12 inches (30 cm)

 

account the anticipated snow line)

 

 

 

 

 

 

 

 

6 inches (15 cm) for

6 inches (15 cm) for

 

 

appliances < 10,000 BTUh;

appliances < 10,000 BTUh;

B

Clearance to window or door that may

12 inches (30 cm) for

9 inches (23 cm) for

appliances > 10,000 BTUh

appliances > 10,000 BTUh

be opened

 

and < 100,000 BTUh,

and < 50,000 BTUh,

 

 

 

 

36 inches (91 cm) for

12 inches (30 cm) for

 

 

appliances > 100,000 BTUh

appliances > 50,000 BTUh

C

Clearance to permanently closed

*

*

window

 

 

 

 

Vertical clearance to ventilated soffit,

 

 

D

located above the terminal within a

*

*

horizontal distance of 2 feet (61 cm)

 

 

 

 

from the center line of the terminal

 

 

 

 

 

 

E

Clearance to unventilated soffit

*

*

 

 

 

 

F

Clearance to outside corner

*

*

 

 

 

 

G

Clearance to inside corner

20 inches (50 cm)

20 inches (50 cm)

 

 

 

 

 

Clearance to each side of center line

3 feet (91 cm) within a height

 

H

extended above meter/regulator

15 feet (4.5 m) above the

*

 

assembly

meter/regulator assembly

 

I

Clearance to service regulator vent

3 feet (91 cm)

*

outlet

 

 

 

 

 

6 inches (15 cm) for

6 inches (15 cm) for

 

 

appliances < 10,000 BTUh;

appliances < 10,000 BTUh;

 

Clearance to nonmechanical air supply

12 inches (30 cm) for

9 inches (23 cm) for

J

inlet to building or the combustion air

appliances > 10,000 BTUh

appliances > 10,000 BTUh

 

inlet to any other appliance

and < 100,000 BTUh,

and < 50,000 BTUh,

 

 

36 inches (91 cm) for

12 inches (30 cm) for

 

 

appliances > 100,000 BTUh

appliances > 50,000 BTUh

K

Clearance to a mechanical air supply

6 feet (1.83 m)

3 feet (91 cm) above if within

inlet

10 feet (3 m) horizontally

 

 

 

Clearance above paved sidewalk or

 

 

L

paved driveway located on public

7 feet (2.13 m) 1

*

 

property

 

 

 

 

12 inches (30 cm) to non-

12 inches (30 cm) to non-

M

Clearance under veranda, porch, deck,

flammables 2

flammables 2

or balcony

24 inches (60 cm) to

24 inches (60 cm) to

 

 

 

flammables 2

flammables 2

 

 

 

 

1A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

2Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local

installation codes and the requirements of the gas supplier.

Rinnai Corporation EX17C / EX22C Manual

19

Page 19
Image 19
Rinnai EX22C, EX17C installation manual Flue Terminal Clearances, Description, Canadian Installations, US Installations