Rinnai EX22C, EX17C Drilling Flue Hole, Configuration viewed from behind the appliance

Models: EX22C EX17C

1 84
Download 84 pages 56.01 Kb
Page 21
Image 21
Drilling Flue Hole

Drilling Flue Hole

Ensure that there are no gas or water lines, or electrical circuits in the wall location where the flue hole is to be drilled.

Drill the flue hole using a 3 1/8 inch (80 mm) drill. The center of the hole must be located anywhere within the shaded area, unless extension kits are used. See diagram.

For weatherboard walls, drill through the center of the weatherboard from the outside first and then through the plasterboard. A template is provided.

For installation without using extension kits, the configuration of the flue manifold, air intake hose, and exhaust slide pipe should be as shown when installation is completed. The shaded area shows where the flue manifold can be located.

Flue Hole

Flue HoleConfiguration viewed from behind the appliance.Manual backgroundManual background1/8"3 mm)(80

Configuration viewed from behind the appliance.

Rinnai Corporation EX17C / EX22C Manual

21

Page 21
Image 21
Rinnai EX22C, EX17C installation manual Drilling Flue Hole, Configuration viewed from behind the appliance